Tanita FitScan BC-1100F Instruction Manual Download Page 2

Introduction

Thank you for selecting a Tanita Body Composition Monitor. This monitor is one in a wide range of 

home healthcare products produced by Tanita.

This Instruction Manual will guide you through the setup procedures and outline the key features.

Please keep it handy for future reference. Additional information on healthy living can be found on our 

website www.tanita.com.

Tanita products incorporate the latest clinical research and technological innovations.

All data is monitored by our Tanita Medical Advisory Board to ensure accuracy.

Note: 

Read this Instruction Manual carefully and keep it handy for future reference.

 Safety Precautions

People with an electronic medical implant, such as a pacemaker, should not use a Body Composition Monitor as it passes a low-level 

electrical signal through the body, which may interfere with its operation.

Pregnant women should use the weight function only. All other functions are not intended for pregnant women.

Do not place this monitor on slippery surfaces such as a wet floor.

Important Notes for Users

This Body fat monitor is intended for adults and children (ages 5-17) with inactive to moderately active lifestyles and adults with 

athletic body types.

Tanita defines “athlete” as a person involved in intense physical activity of approximately 10 hours per week, for 

at least 6 months, and who has a resting heart rate of approximately 60 beats per minute or less.

Tanita’s athlete definition includes “lifetime of fitness” individuals who have been fit for years but currently 

exercise less than 10 hours per week.

The body fat monitor function is not intended for pregnant women, professional athletes or bodybuilders.

Tanita takes no responsibility for any kind of damage or loss caused by these units, or any kind of claim made by a third person.

Note:

  Body fat percentage estimates will vary with the amount of water in the body, and can be affected by dehydration or over-

hydration due to such factors as alcohol consumption, menstruation, illness, intense exercise, etc. It is recommended that if 

possible all readings should be taken at the end of one’s day since in the morning after rising from sleep, hydration levels are 

at their lowest.

Features and functions

Measuring Platform

Accessories

1. Indicator light (Green and Red)

2. Ball-of Foot Electrodes

3. Heel Electrodes

4. AA-Size Batteries (4)

Summary of Contents for FitScan BC-1100F

Page 1: ...Model FitScan BC 1100F MANUAL Instruction Manual Read this Instruction Manual carefully and keep for future reference ...

Page 2: ...onitor is intended for adults and children ages 5 17 with inactive to moderately active lifestyles and adults with athletic body types Tanita defines athlete as a person involved in intense physical activity of approximately 10 hours per week for at least 6 months and who has a resting heart rate of approximately 60 beats per minute or less Tanita s athlete definition includes lifetime of fitness ...

Page 3: ...oid soaps Do not step on the platform when wet Do not drop any objects onto the platform Do not use this scale while operating transmitters such as a cell phone as this may affect your results If not in use for a prolonged period of time it is recommended that you remove the batteries Getting accurate readings To ensure accuracy readings should be taken without clothing and under consistent condit...

Page 4: ...m of each other 2 Press and hold OFF button for 2 seconds on the remote display The remote display will show 1234 for selecting a personal number Select the preferred personal number which will be paired with the platform using s t buttons and press the SET button to confirm 3 The remote display will show SEt P Select YES or no using s t buttons and press the SET button to confirm a YES The pairin...

Page 5: ...ash all data three times to confirm the programming The power will then shut down automatically Taking body composition readings 1 Before proceeding make sure that the platform and remote display are within 17 feet 5 m of each other 2 Press t User button to turn the unit on and then press s t buttons to select personal data number Do not stand on the platform 3 Press the SET button to confirm your...

Page 6: ...ea Do not step onto the platform before the platform beeps once and the Green Indicator Light blinks Do not step off until after hearing a double beep or the Green Light remains solid stops blinking the measurement is taken and the readings are displayed on the applicable device e g Tanita Remote Display and or PC If you do not step onto the platform within 30 seconds after Green Indicator Light b...

Page 7: ... found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communic...

Reviews: