What is Body Fat Percentage?

Body fat percentage is the percentage of fat in your body. Until now, your absolute weight has
determined whether or not you were considered overweight or obese. In recent years, the definition of
obesity has been refined to mean the presence of excess body fat. Obesity has been linked to conditions
such as high blood pressure, heart disease, diabetes, cancer, and other disabling conditions.

The BIA Method

Tanita Scale plus Body Fat Monitors use the BIA (Bioelectrical Impedance Analysis) technique. In this
method, a safe low-level electrical signal is passed through the body. It is difficult for the signal to flow
through fat in the human body, but easy to flow through moisture in the muscle and other body
tissues. The difficulty with which a signal flows through a substance is called impedance. So the
amount of fat in the body can be accurately estimated by measuring the impedance. The signal used is
very low, making it safe and imperceptible.

The illustration on the left shows how the signal travels through the body.

Body Fat Percentage Fluctuations in a Day

Hydration levels in the body may affect body fat readings. Readings are usually highest in the early
waking hours, since the body tends to be dehydrated after a long night’s sleep. For the most accurate
reading, a person should take a body fat percentage reading at a consistent time of day under
consistent conditions.

Besides this basic cycle of fluctuations in the daily body fat readings, variations may be caused by
hydration changes in the body due to eating, drinking, menstruation, illness, exercising, and bathing.
Daily body fat readings are unique to each person, and depend upon one’s lifestyle, job and activities.

Advantages of Tanita Scale plus Body Fat Monitors

Previously, body fat percentage was determined by measuring the thickness of subcutaneous fat by
pinching it with calipers, or by laying a person on a scanning bed and passing a current from hand to
foot. However, these methods had problems—professional skills are required, the procedures take
time and are often invasive, and measurement values vary. Currently, the gold standard methods of fat
percentage measurement are the 

underwater weighing method

and

DEXA

(

dual energy x-ray

absorptiometry

).

Tanita’s BIA method uses equations derived from large, multi-ethnic population studies to predict body
composition. Readings taken with Tanita Scale plus Body Fat Monitors correlate highly with both DEXA
(Tanita’s reference model) and Hydrodensitometry.

20–39

40–59

60–79

Healthy

Overfat

Obese

Underfat

Healthy

Overfat

Obese

Underfat

Based on NIH/WHO BMI Guidelines.

     
As reported by Gallagher, et al, 
at NY Obesity Research Center. 

 
To determine the percentage of body fat 
that is appropriate for your body, 
consult your physician.

10%

0%

20%

30%

40%

20–39

40–59

60–79

Female

Body Fat Ranges 

for Standard Adults

 

Age

Male

Age

1, 2

1

2

BF-625/626 Scale plus Body Fat Monitor

2

Tanita’s patented “foot-pad”
design sends a safe, 
low-level electrical signal
through the body to
determine its composition.

PRINCIPLES OF ESTIMATING BODY FAT %

Summary of Contents for BF-625

Page 1: ...Lisez ce manuel d instructions attentivement et gardez le à portée de la main pour référence future Manual de Instrucciones Lea cuidadosamente este Manual de Instrucciones y guárdelo para consultarlo en el futuro BF 625 BF 626 Scale plus BodyFat Monitor Balance impédancemètre Monitor de Grasa Corporal Báscula Pesa ...

Page 2: ... not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equi...

Page 3: ...nute or less Tanita s athlete definition includes lifetime of fitness individuals who have been fit for years but currently exercise less than 10 hours per week Tanita s athlete definition does not include enthusiastic beginners who are making a real commitment to exercising at least 10 hours per week but whose bodies have not yet changed to require the Athlete mode Body fat percentage estimates m...

Page 4: ... time of day under consistent conditions Besides this basic cycle of fluctuations in the daily body fat readings variations may be caused by hydration changes in the body due to eating drinking menstruation illness exercising and bathing Daily body fat readings are unique to each person and depend upon one s lifestyle job and activities Advantages of Tanita Scale plus Body Fat Monitors Previously ...

Page 5: ...creen 2 Set Button 3 UP Down Select Buttons 4 Ball of Foot Electrodes 5 Heel Electrodes 6 Personal Keys Accessories 7 AA Size Batteries 4 8 Support Feet 4 Only needed if unit is placed on carpet Do not use these feet on hard flooring 2 3 4 5 6 1 3 7 8 ...

Page 6: ... carpeting that is more than 0 8 20 mm in thickness and do not use the support feet on hard uncarpeted surfaces as the unit may tip over Handling Tips This monitor is a precision instrument utilizing state of the art technology To keep the unit in the best condition follow these instructions carefully Do not attempt to disassemble the measuring platform Store the unit horizontally and place it so ...

Page 7: ...the type of operation If an extraordinary weight is applied to the platform If you make a mistake during measurement or a key or button operation During programming if you do not touch any of the keys or buttons within 60 seconds After you have completed the measuring process Note If the power shuts off automatically repeat the steps from Setting and Storing Data in Memory p 6 Your Scale plus Body...

Page 8: ...ns to select Female or Male arrows will point to the icons indicating the gender Then press the Set button The unit will beep once to confirm BF 626 Select Athlete Mode Use the Up Down buttons to scroll through Female or Male Female Athlete or Male Athlete As you scroll the Female icon appears first the Male icon second then the female icon appears with an arrow that points to the athlete icon ind...

Page 9: ... hydration If you do not undress always remove your socks or stockings and be sure the soles of your feet are clean before stepping on the measuring platform Stand erect on the platform Be sure that your heels are correctly aligned with the electrodes on the measuring platform Don t worry if your feet appear too large for the unit accurate readings can still be obtained if your toes overhang the p...

Page 10: ...he unit will beep twice and the display will show 0 0 Step onto the platform Next follow the directions for Get Your Readings p 7 Note If you step onto the platform before 0 0 appears the display will show Error and you will not obtain a reading Reprogramming a Personal Key From time to time you may need to adjust the data stored in a Personal Key for example your age or height or for the BF 626 t...

Page 11: ...ligned with the guides on the measuring platform Consider whether or not you have selected the correct Personal Key and make sure that you wait for 0 0 to appear before stepping on the platform Step off and repeat steps on p 7 OL appears while measuring Reading cannot be obtained if the weight capacity 300 lb 136 kg 21 st 6 lb is exceeded Note If body fat percentage is more than 75 readings cannot...

Page 12: ...on is authorized to change the terms of this warranty If Product Is Defective or Needs Repair Do not return this product to the place of purchase doing so may delay the processing of your warranty claim Call Tanita at1 800 TANITA 8 to receive a Return Authorization Number before returning this product Include 12 50 for handling return postage and insurance to the facility listed below Proof of pur...

Page 13: ...st for repair and or placement of an order for parts or products Or call 1 800 TANITA 8 USA and Canada only Caractéristiques BF 625 626 Charges admises 300 lb 136 kg 21 st 6 lb Gradation 0 2 lb 0 1 kg 0 2 lb Précision du pourcentage de graisse 0 1 Alimentation 4 piles AA CC 6V de type UM3 incluses Consommation d énergie 60 mA au maximum Courant émis 50 kHz 500 µA UPC No BF 625 LG Light Gray 742496...

Reviews: