Changing the Dry Cell Batteries

Even if the batteries are removed, memorised personal data 

(birthdays, gender, heights and measurement figures)

will not be deleted

.

If the dry cell batteries are exhausted, 

starts to flash on the display. (You cannot operate the equipment or perform

measurement.)

Please change all four batteries immediately to ensure continued accuracy. 
* While 

is flashing, even if you remove the dry cell batteries, the set date and time are

maintained (for about five minutes.)
Please change the dry cell batteries as quickly as possible.

* Never use alkaline dry cell batteries together with manganese dry cell batteries, as this may cause

malfunction.

After changing the dry cell batteries, the following displays appear. Please follow each instruction and operate the
equipment accordingly.

Lo

Lo

When you put dry cell batteries in
for the first time after purchasing 
the equipment, the product will ask
you to check the calender.

The life of the dry cell batteries is about 1 year if the
product is used once a day. The life of the batteries

included may be shorter than stated above.

When changing dry cell batteries or operating the equipment, if the LCD behaves oddly or the switch does not work,
please remove the batteries, wait until the LCD clears (for about five minutes) and put the batteries back in again.

Display

Press the 

and check the date and time in the

calendar.
•If the date or time is wrong, please correct it. (See How to change

the calendar on page 21.)

•When 

is displayed, please set the calendar. 

(See

Calendar Setting

on page 10.)

Time/DOWN

Locate the battery compartment behind the display box.

open the battery box cover.

put in the AA R6P dry 
cell batteries. (Included)

Loading the batteries

U

When flashes 

for

a few seconds and then
disappears.

Lo

When nothing is displayed.

When is 

displayed.

Please set the calendar. (See 

the Calendar Setting

on page 10.)

Use

9

GB

GB

2

Connect the Display Box to the Scale
Platform

Be sure to hold the plug at the end of the connection
cable and insert it into the display box. (Insert it straight
into the box so that the triangle signs on both sides
meet.)

Be sure to insert and pull out the connection cable by
holding the plug at the end of the connection cable.

Otherwise this may damage the product.

1

Installing the Scale Platform

Use this equipment on a hard flat surface.

If using the unit on soft carpets, attach the carpet feet.

With the carpet feet you can
perform measurement even on
carpets up to 20 mm thick.

Caution

Do not use carpet feet except on carpets.

This could make the product unstable.

Do not damage the connection parts or connection
cable.

If you use force to bend, pull, twist or step on them, this may cause

failure or malfunction.

Do not carry the equipment by holding it only by
the connection cable.

This may cause failure, breakage or malfunction, and there is a risk of

damage if you drop the equipment.

Support
(Attached)

Support
Hole

Correct way
to attach foot

Wrong way to
attach foot

Caution

Preparation

8

BF-562海外GB+D面付解除 ページ9

Summary of Contents for BF-562

Page 1: ...Instruction Manual For Home Use Please note Improper use of this product could cause serious injury or damage to the product or other property Please read this manual carefully before use and keep aside for future reference BF 562GB解除 裏から3 ページ1 ...

Page 2: ...he product You could slip or fall and suffer serious injury Disabled persons should not use the equipment unassisted Use a handrail or obtain the assistance of a nurse or carer If using a handrail the readings obtained will only provide a rough indication of the user s actual weight and body fat percentage CAUTION Indicates the possibility of injury or damage to equipment if instructions are ignor...

Page 3: ...box cover on the back of the display box insert the hooks of the large bracket into the holes on the bottom to attach the display box Always use the attached screws to attach the bracket for wall installation If you attach the bracket with double sided sticking tape for example it may fall down Ensure that the display box is firmly hooked on the bracket for wall installation If the display box is ...

Page 4: ... time is wrong please correct it See How to change the calendar on page 21 When is displayed please set the calendar See Calendar Setting on page 10 Time DOWN Locate the battery compartment behind the display box open the battery box cover put in the AA R6P dry cell batteries Included Loading the batteries U When flashes for a few seconds and then disappears Lo When nothing is displayed When is di...

Page 5: ...if the calender is not set Points to Note Automatic Power Off Function In order to save power the unit will automatically switch off after use The display disappears The automatic power off function also works in the following case When the button operations are stopped Although it depends on the operation concerned the power will be switched off after about 20 to 30 seconds If you have made a mis...

Page 6: ...ation takes you back to the registration of your birthday please start the registration again In order to register with another number eAfter the display disappears please start over again When you want to change memorised data for another individual s data ePlease refer to Correction and Alteration of Personal Data on page 22 Personal GRAPH The display shows as right and the number blinks Persona...

Page 7: ...e power will be switched off after about 20 to 30 seconds When about 30 seconds have passed without you stepping on the scale platform after 0 0 kg is displayed When you stepped off the scale platform during the measurement When about 30 seconds have passed since the graph was displayed Automatic Power Off Function GB GB Memory key for five individuals Personal If the display box and the scale pla...

Page 8: ...ge This product was researched and developed using bioelectrical impedance analysis BIA which is a method of determining body fat percentage by measuring the body s electrical resistance Fat in the body conducts hardly any electricity whereas the water contained in muscles is a good conductor of electricity Measuring electrical resistance thus offers a way of determining the proportion of fat and ...

Page 9: ...ECORDED is displayed for the first time press your Memory Key again within one minute Measure yourself Personal The BMI is displayed followed by the graphs and the power is switched off When NOT RECORDED Is Displayed While recording the results of your measurement sometimes NOT RECORDED is displayed and you cannot record the data Ensure that you use your own Memory Key Personal 1 4 When NOT RECORD...

Page 10: ...st profits or any claims by a third party arising from the use of this equipment SELECT YOUR NO will be displayed and the Memory Key will blink Personal Remarks If NO DATA is displayed eMeasurements were not recorded at the time to which the cursor is pointing This is not a malfunction The displayed figures are weekly and monthly averages When you want to end the graph display function ePress butt...

Page 11: ...the scale platform barefoot so that your heels touch the center of the electrodes After kg is displayed 0 0 2 To Start Measuring Measurement is finished your body weight and the Body Fat Percentage will be displayed for about three seconds Two short beeps will sound The BMI figure is displayed The unit will switch off Note When measured in the athlete mode the BMI figure will not be displayed Pres...

Page 12: ...n before altering the pre recorded data 2 Altering the pre set details Following the displayed instructions alter the data See Before Measurement Registration of Personal Data on page 14 for details To enter corrections for body type Adult Athlete Height etc e g To change the height data as a child grows The measurement results recorded against the Memory Key will not be deleted Personal When alte...

Page 13: ...eshooting RefertoPage Recorded Measurements Exchanging your Memory Key for another individual s Memory Key Personal Personal Exchanging another individual s Memory Key for your Memory Key Personal Personal Altering the date of birth year month day pre set against a Memory Key Personal Altering the gender male female pre set against a Memory Key Personal s Correcting the body type athlete pre set a...

Page 14: ...m increments Power Source AA Dry Cell Batteries R6P x 4 Power Consumption DC6V Maximum 60mA Specifications This product is not legal for trade Points to Note Instructions for registration of date of birth You can register dates of birth for individuals aged from one to 90 years For individuals aged 91 years or older register the birthday so that he she is 90 years old For individuals aged six or y...