background image

- 12 - 

 
For the example values given in a, b and c the result is: 
 

 62 

100 

g =   

 

 

=     0.56 

 

94.2 

100 + 17.2 

 
e)   now you can use the calculated density (e.g. 0.56) for 

any future measurements of this type of timber. 

 
 

9.   Errors 

 

If the instrument can not calibrate properly it indicates 

the following error: 

 -AIr

   

- generator voltage too low 

  AIr

 

 

- generator voltage too high 

 
In such case power off the device, check the geometry of 
the electrodes, clean the electrodes, make sure the device is 
dry and then start the calibration again (see chapter 4). 

If the instrument still reports error contact the 

producer. 
 

- 5 - 

 
Density values for other (also exotic) wood types are in 
chapter 7 of the users manual. 

 

5. Measurements 

 

The measurements should be conducted in at least 

several places. These places should be as flat, smooth and 
clean as possible. The actual result of the measurements is 
the arithmetic average of all the measurements. A line 
drawn between the electrodes should be perpendicular to 
the fibres. If the timber is too thin, place the electrodes 
parallel to the fibres. 

Hold the device as shown on fig 2. Press the electrodes 

hard against the wood. Read the result. 

There should not be any metal elements, wet wood or 

concrete etc under the timber. It’s best if the timber is 
supported only by it’s ends or placed on a layer of 
Styrofoam several centimetres thick. 

The instrument is equipped with an automatic power 

off which activates 5 minutes after the last change in upper 
control knob setting. It can be switched off instantly by 
setting the upper control knob to OFF. 

Summary of Contents for WIP-22D

Page 1: ...enerated by the device The Moisture Meter is equipped with knobs for setting the density and thickness of the wood It can be used to measure wood planks 10 mm to 60 mm thick and of density within the...

Page 2: ...ower knob THICKNESS setting the thickness with the lower knob SETTINGS CHECK alternately displaying the previously set density and thickness MEASURE automatic calibration approx 4 sec and measurement...

Page 3: ...quickly switch the upper control to SETTINGS CHECK The LCD will display the density and thickness set during the previous measurements e g 0 56 and 42 Hold the device in the air fig 1 switch the uppe...

Page 4: ...isplayed on the LCD The device is ready for measurements A table with the density values for the most popular wood types is on the back of the moisture meter 13 10 Changing the battery The device is e...

Page 5: ...surements The measurements should be conducted in at least several places These places should be as flat smooth and clean as possible The actual result of the measurements is the arithmetic average of...

Page 6: ...trodes get deformed they should be bend to their original shape Deformed or misplaced electrodes are the 11 b weight the cube with the accuracy of 1 gram note the result G in grams e g 62g c measure t...

Page 7: ...mm calculate it s volume in cm3 V a b h e g 94 2 cm3 7 source of errors and in extreme cases can prevent proper calibration of the device Avoid measurements when the timber or the operator of the devi...

Page 8: ...0 74 Mahogany Broad 0 55 Mahogany Grand Bassam 0 47 Mansonia 0 6 Maple 0 59 Maple 0 58 Maple sugar 0 63 Maple soft 0 47 9 Meranti dark red 0 67 Meranti White 0 82 Merbau 0 77 Niangon Wishma 0 6 Oak E...