14
FEATURES
WATER FLOW CONTROL ADJUSTMENTS
The ChekPoint controller offers a selection of pre-set flow control adjustments. These selections
are made by configuring a bank of seven switches, SW(1) to SW(7), according to the tables below.
The flow control switches are located behind the battery cover just above the batteries. Note SW
(8) is not used.
AUTO TIME-OUT ADJUSTMENT (SWITCHES 1-3)
The ChekPoint controller provides six periods to select from for shutting off the water when the
object is left in front of the electronic eye. The time periods to select from are: 15 seconds, 30
seconds, 45 seconds, 60 seconds, 3 minutes and 20 minutes. The default setting is 15 seconds.
Note: The chart below indicates the switch positions required for each auto time-out mode.
AUTO-FLUSH (SWITCH 4)
The ChekPoint controller offers the option to select the Auto Flush mode in switch 4 position.
When enabled, the controller will flush the ChekPoint faucet approximately every 12 hours for 25-
30 seconds when the faucet is not used. Default setting from the factory is in the “off” position.
WATER SHUT-OFF DELAY
ADJUSTMENT (SWITCHES 5 & 6)
The ChekPoint controller provides four
periods to select from for shutting off the
water when the object is removed from in
front of the electronic eye. The time periods
to select from are: 1 second, 10 seconds, 15
seconds, and 30 second. The default setting
is 1 second.
PERIOD
15 seconds
30 seconds
45 seconds
60 seconds
3 minutes
20 minutes
SW(1)
OFF
OFF
OFF
OFF
ON
ON
SW(2)
OFF
OFF
ON
ON
OFF
OFF
SW(3)
OFF
ON
OFF
ON
OFF
ON
PERIOD
1 seconds
10 seconds
15 seconds
30 seconds
SW(5)
OFF
OFF
ON
ON
SW(6)
OFF
ON
OFF
ON
Auto Time Out Selection
Water Shut Off Delay Selection
Auto Flush Mode
SW (4)
ON - (Enable)
OFF - (Disable)
Metering Mode
SW (7)
ON - (Enable)
OFF - (Disable)
METERING MODE (SWITCH 7)
In metering mode, when activated the faucet will remain on for 15 seconds regardless if an object
is in front of the eye or if it is removed and returned to the front of the eye. After 15 seconds, the
sensor resets for another activation.
EN
Summary of Contents for EC-3113 Series
Page 2: ...2 Exploded View ...