evolution 5000 E5780 and E5782 Encoder
18
Navigate to the
Remote Control
Menu
. Select the following options:
!
IP Address Option – enter or change the IP address of the unit.
!
Serial Protocol Option – select RS-485 or RS-232.
!
Change other options as required.
4.4
Set the Mux Options
Navigate to the
Mux
Menu
. Select the following options:
!
Packet Length Option – select either 188 (typical) or 204 bytes.
!
On Air – set to On to send the output of the Encoder to the
Multiplexer.
!
Bit-rate (188) / Bit-rate (204) Options – select the required
bit-rate.
NOTE
If the Packet Length option is set to 188 bytes then only the
Bit-rate (188) option is displayed. If the Packet Length option is set
to 204 bytes then both the Bit-rate (188) and Bit-rate (204) options
are displayed.
4.5
Set the Video Options
Navigate to the
Video
Menu
and select the
Video Encoder
Menu
to
configure the video input to the Encoder. Select the following options:
!
Profile\Level Option – select MP@ML, 422P@ML, MP@HL or
422P@HL.
NOTE
This option is always MP@ML or MP@HL and cannot be changed
unless the M2/ESO2/422 or M2/ESO2/HD422 software option is
enabled.