evolution 5000 E5780 and E5782 Encoder
17
Refer the following steps for a typical set-up. See Figure 4.1 for the
menu tree and Section 4.1 onwards on how to navigate the menus. For
more detailed information or parameters not mentioned refer to the
Reference Guide.
!
Select the syntax.
!
Optional - load a default configuration and amend if necessary or
restore the factory defaults. Refer to Section 5 for examples of
typical configurations.
!
Set the remote control options.
!
Set the mux options.
!
Set the video options.
!
Set the audio options.
!
Set the data options.
!
Set the output options.
4.1 Select
Syntax
Navigate to the
Service Info Menu
and select the Syntax option.
Choose DVB or ATSC, as required. The service information for the
service can then be set in the
Service Info Menu
.
4.2
Load Default Configuration/Restore Factory Defaults
From the Summary screen navigate to the
Configs
Menu
. Select Load
Active Config and choose one of the configurations. Amend the
parameters as necessary.
4.3
Set the Remote Control Options
If the Encoder is to be controlled via its Ethernet interface the unit's IP
address and associated parameters must be set in the
Remote Control
Menu
.
Alternatively, if the Encoder is to be controlled via RS-232/RS-485, the
serial protocol, baud-rate and unit address must be set in the
Remote
Control Menu
.