background image

D13841.08
10.2007

17

TANDBERG 

3G GATEWAY 

USER GUIDE

Table of 

Contents

Trademarks & 

Copyright

Patents & 

Disclaimers

Safety/ 

Environmental

To Get You  

Up and Going

Using the 3G 

Gateway

Viewing the 

System Status

Configuring  

the 3G Gateway

Maintenance  

& Upgrade

Services

Dial Plan 

Examples

Contact 

Information

Using the 3G 

Gateway

TANDBERG 

3G GATEWAY 

USER GUIDE

To start the 3G Gateway, simply connect the 
power cable, and set the power switch button 
(both at the rear) to position 

I

On the front panel of the system the power 
indicator LED, marked 

PWR

, will turn 

GREEN

.

Power switch

Accessing the 3G Gateway

Forgot the Password?

The 

pwrec

 account is active for one minute following a restart. 

Beyond that time, the system will have to be restarted to 
change the password. 

3G Gateway Start-up

 

Reboot the 3G Gateway.

 

Connect to the 3G Gateway via the serial interface once it has 

restarted.

 

Login with User Name 

pwrec

.  

No password is required.

 

You will be prompted for a new password.

Starting Up the 3G Gateway

You may access the 3G 
Gateway by entering the IP-
address of the 3G Gateway 
in a standard WEB-browser. 
You will then be asked to 
enter a password. You will 
need to enter 

admin

 as 

user name. The default 
password for the 3G Gateway 
is 

TANDBERG

. Remember 

that the password is case 
sensitive. Note that you may 
also use SSH and Telnet to 
configure the 3G Gateway.

USER NAME

 is 

admin

PASSWORD

. Default 

password is 

TANDBERG

 (NB! 

case sensitive)

Summary of Contents for 3G GATEWAY 1

Page 1: ...right Patents Disclaimers Safety Environmental To Get You Up and Going Using the 3G Gateway Viewing the System Status Configuring the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information Software version R3 D13841 08 OCTOBER 2007 ADMINISTRATOR GUIDE 3G GATEWAY ...

Page 2: ...the Management Menu System 18 Service Call Details 19 Call Setup via Default Services 20 Dialing from UMTS Using Phone Book 21 Viewing the System Status ISDN PRI Status PRI Versions only 23 ISDN BRI Status BRI Versions only 24 H 323 Gatekeeper Status 25 Services 26 System Information 27 System Resources 28 Configuring the 3G Gateway ISDN PRI Configuration ISDN PRI Versions only 30 ISDN BRI Configu...

Page 3: ...opyright All rights reserved This document contains information that is proprietary to TANDBERG No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronically mechanically by photocopying or otherwise without the prior written permission of TANDBERG Nationally and internationally recognized trademarks and trade names are the pro...

Page 4: ...isclaimers Safety Environmental To Get You Up and Going Using the 3G Gateway Viewing the System Status Configuring the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information Patents Disclaimers TANDBERG 3G Gateway USER GUIDE Disclaimer License Agreements and Patent Information ...

Page 5: ...rietary to TANDBERG No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronically mechanically by photocopying or otherwise without the prior written permission of TANDBERG Nationally and internationally recognized trademarks and trade names are the property of their respective holders and are hereby acknowledged Copyright 1992...

Page 6: ...es Dial Plan Examples Contact Information Safety Environmental TANDBERG 3G Gateway USER GUIDE For your own protection please read the overleaf safety instructions completely before operating the equipment and keep this manual for future reference The information in this summary is intended for operators Carefully observe all warnings precautions and instructions both on the apparatus and in the op...

Page 7: ... attached power supply cord to other products In case any parts of the product has visual damage never attempt to connect mains power or any other power source before consulting service personnel The plug connecting the power cord to the product power supply serves as the main disconnect device for this equipment The power cord must always be easily accessible Route the power cord so as to avoid i...

Page 8: ...ective bans the use of certain heavy metals and brominated flame retardants to reduce the environmental impact of WEEE which is landfilled or incinerated TANDBERG has implemented necessary process changes to comply with the European RoHS Directive 2002 95 EC and the European WEEE Directive 2002 96 EC Waste Handling In order to avoid the dissemination of hazardous substances in our environment and ...

Page 9: ...figuring the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information Safety Environmental TANDBERG 3G Gateway USER GUIDE 12 TANDBERG CONTENT SERVER USER GUIDE Table of Contents What s New in this Version Trademark Licenses Safety Environmental Introduction Installation Quick Setup Operation Administrator Settings Conference Setup View Conferences Appendices D13898 04 DECEMBE...

Page 10: ...the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information To Get You up and Going TANDBERG 3G Gateway USER GUIDE To get You Up and Going Before you start using the system we recommend that you take your time to read through this section of the User Guide to get you up and going This section outlines how to connect the system and the basic operating principles ...

Page 11: ...lease report any discrepancies to your TANDBERG representative immediately Make sure that the 3G Gateway is accessible and that all cables can be easily connected For ventilation Leave a space of at least 10cm 4 inches behind the 3G Gateway s rear panel and 10cm 4 inches in front of the front panel The room in which you install the 3G Gateway should have an ambient temperature between 0ºC and 35ºC...

Page 12: ... the TANDBERG Management Suite to control the 3G Gateway HTTP Web interface for system management call management such as diagnostics and software uploads HTTPS Hypertext Transfer Protocol over Secure Socket Layer is a Web protocol that encrypts and decrypts user page requests as well as the pages that are returned by the Web server It uses Secure Socket Layer SSL as a sublayer under its regular H...

Page 13: ... Alarm Indicator RAI means that the 3G Gateway is receiving framing info but in this framing info the other side tells the 3G Gateway that it is not reading the Gateway s transmitted framing information Typically this may be a broken connector in the transmit TX part of the PRI cable This could also indicate weak or noisy signal in the transmit TX part of the PRI cable Blue Alarm indicates that th...

Page 14: ... static IP address type Xconf ip Assigment Static and Xconf ip address IPAddr To assign an IP Subnetmask type Xconf ip address subnetmask subnetmask To assign an IP Gateway address type Xconf ip address gateway gateway IP address Restart the 3G Gateway Start a WEB browser and enter the IP address of the 3G Gateway Default password TANDBERG Note the case sensitivity To configure the 3G Gateway for ...

Page 15: ...ce the Main Menu Use UP DOWN to navigate to the IP Settings if needed Press ENTER to access the IP Settings submenu Use the UP DOWN keys to select IP Address In addition to configure the IP address you must also configure the default gateway netmask and set IP assignment to static Press ENTER again to produce the cursor Use up down keys to navigate between the digits of the number Use ENTER to ent...

Page 16: ...figuring the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information Using the 3G Gateway TANDBERG 3G Gateway USER GUIDE Using the 3G Gateway This section of the 3G Gateway User Guide shows you how to gain access to the system how to get an overview of ongoing calls the menu operating principles and how to dial from UMTS as well as from IP Examples are provided for your conv...

Page 17: ...sword The pwrec account is active for one minute following a restart Beyond that time the system will have to be restarted to change the password 3G Gateway Start up Reboot the 3G Gateway Connect to the 3G Gateway via the serial interface once it has restarted Login with User Name pwrec No password is required You will be prompted for a new password Starting Up the 3G Gateway You may access the 3G...

Page 18: ... of the 3G Gateway can be accessed via the default URL http 3G Gateway_IP_ Address overview Service Indicates the service type i e DID IVR TMS phonebook Duration Duration of the call in hours minutes and seconds An Overview of the Management Menu System Remote Number This is the inbound number Net Indicates the net type i e H 323 H 324m SIP or Streaming Actions Clicking on view details reveals bot...

Page 19: ...s of the Incoming calls are the numbers of the calling party and remote numbers of the Outgoing calls are the numbers of the called party or service Clicking View details reveals the Call Details i e details belonging to the respective call leg The View Call Details tab presents information about all calls routed through the 3G Gateway i e inbound and outbound numbers duration of the calls and cal...

Page 20: ...enu an outbound call to another endpoint e g a 3G Mobile H 323 or SIP endpoint can be set up DID Direct Inward Dialing Example Hotline Entry details Enabled Check Name H 324m H 323 Net Type H 324m Prefix 67890000 Suffix Service Type Direct Inwards Dialing Arguments Net Type H 323 AV Mode Auto fallback to audio Prefix 51234 Suffix Use Remainder No Allow Forwarding No When dialing number 67890000 th...

Page 21: ...mes results in vo If one wants to reach Tom Arne press 8 followed by three times 6 i e search string to To select the person you wish to dial press the corresponding key to place a call to that person 3 The star key on the keypad is used as backspace The TMS Corporate Directory service allows one Endpoint i e a UMTS phone H 323 or SIP to dial another Endpoint directly without knowing or having to ...

Page 22: ... Viewing the System Status Configuring the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information Viewing the System Status TANDBERG 3G Gateway USER GUIDE Viewing the System Status To view the current status of the system hover with the mouse pointer over Status to produce a drop down menu as shown here This section discusses the respective menu items ...

Page 23: ...e indications the ISDN interface also contains 4 LEDs located at the the 3G Gateway rear panel These LEDs indicate the following PRI status Green Normal operation Red Alarm or Loss of signal LOS indicates that there is no signal and thus no framing info received A defect or unplugging the PRI cable will produce the same effect Yellow Alarm or Remote Alarm Indicator RAI means that the 3G Gateway is...

Page 24: ...n indicates up and in sync Red indicates not in sync and indicate probably a disconnected ISDN line Besides the indications on the webpage each ISDN BRI interface located at the back side of the 3G Gateway has a green and orange LED The meanings of these LEDs are Green Layer 1 of the ISDN signalling is up Green and Orange This indicates that both layers 1 and 2 are up In some countries the orange ...

Page 25: ...H 323 Gatekeeper Status shows the current status of the Gatekeeper registration To view H 323 gatekeeper status as indicated in the screenshot shown here select H 323 Status item of the Status tab In case the 3G Gateway is in direct mode or in case the gatekeeper IP address is filled in incorrectly the 3G Gateway will not be registered with the Gatekeeper and the Registration status is stated as I...

Page 26: ... Up and Going Using the 3G Gateway Viewing the System Status Configuring the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information Viewing the System Status TANDBERG 3G Gateway USER GUIDE The default services which come standard with an 3G Gateway system are Direct Inwards Dialing IVR TMS Corporate Directory Services ...

Page 27: ...oing Using the 3G Gateway Viewing the System Status Configuring the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information Viewing the System Status TANDBERG 3G Gateway USER GUIDE This pane provides an overview of installed software and hardware Select System Information to access the System Information pane System Information ...

Page 28: ...s TANDBERG 3G Gateway USER GUIDE To view available resources of the 3G Gateway open System Resources of the Status tab as shown here This menu item shows the amount of active sessions i e video and audio calls on this system The system load percentage indicates the processor load These figures depend on the system s use of resources The use of Call Forwarding in dial plans reduces system load and ...

Page 29: ... Gateway USER GUIDE Configuring the 3G Gateway To configure the 3G Gateway hover with the mouse pointer over the System configuration to produce a drop down menu The drop down menu consists of 6 7 items i e ISDN IP H 323 SIP SNMP and System to configure respective system parts Changing settings in the menus belonging to the ISDN IP and System items only become effective after a system reboot there...

Page 30: ...Japan Taiwan ISDN Save When all settings are entered click on Save to store the new settings Note that changing from E1 to T1 configuration requires a restart of the unit click Restart to restart the unit Enable CRC 4 Used for most E1 PRI configurations If your network equipment does not support this feature switch off PRI CRC 4 ISDN PRI Configuration ISDN PRI Versions only All incoming calls are ...

Page 31: ...d video telephone calls H 324M This ITU standardized capability is selected for outgoing calls by default UDI In some situations the switch does not accept calls which use the correct H 324M capability This setting makes it possible to use the 3G Gateway in these situations via selecting UDI Select BRI to access the BRI Configuration pane You cannot configure ISDN BRI lines for special functions l...

Page 32: ...C The Circuit Identification Code is a unique identifier for a data time slot in a cable trunk In this case the CIC acts as base address and can be defined for each SS7 trunk and sets the first time slot number of the respective SS7 trunk Link Set Details A link is a time slot within a trunk used for signalling Link sets are typically used for signalling fail over purposes to one switch Enabled Ch...

Page 33: ...OPC DPC and Circuit Identification Code CIC The absolute CIC consist of a CIC base address which has to be defined for each trunk in the SS7 window i e in this case 0 32 64 and 96 and a relative address The latter is a number between 0 and 31 and depends on the choice of the framing time slot and signalling time slot numbers Since one time slot is reserved for framing in this case set to time slot...

Page 34: ...lling fail over is arranged via two switches and two Signalling Transfer Points STPs over 2 link sets as can be seen from the schematic and the SS7 window below Since the trunks are terminated by the switches the DPCs of trunk 1 and 2 are 100 and 101 respectively However both links are terminated by the STPs Link set 1 contains SS7 trunk 1 and is terminated by an STP with DCP 200 Link set 2 contai...

Page 35: ...s for these fields By default these fields are set to 127 0 0 1 Date and Time Settings An NTP server address can be specified here to provide the 3G Gateway with up to date time and date information Restart This button will restart the 3G Gateway Any changes made in the IP Configuration of the 3G Gateway will take effect after the system has been restarted IP Configuration IP Ethernet Speed provid...

Page 36: ...3G Gateway requires the use of H 323 numbers E 164 aliases and service prefixes This means that the 3G Gateway must be registered to a Gatekeeper select the H 323 menu item in the Configuration menu H 323 Configuration If the Gatekeeper is configured with an alternative Gatekeeper the Status area may report a registration to the IP address of the alternative Gatekeeper In case password is not set ...

Page 37: ...G 3G Gateway USER GUIDE SIP settings Enabled 3G Gateway will use this Proxy for call setup Select SIP to access the SIP Configuration pane Save When ready to store the new settings press Save These settings will take effect when the system has been restarted Setting Mode to Off will not hide the SIP proxy address and port settings SIP proxy address Enter the IP Address of the proxy server to which...

Page 38: ...etwork The 3G Gateway s SNMP Agent responds to requests from SNMP Managers a PC program etc SNMP traps are generated by the agent to inform the manager about important events SNMP Mode The SNMP operation modus can be set to On Turns SNMP On Off Turns SNMP Off ReadOnly Do not send SNMP information to the host TrapsOnly Only send SNMP information identified as TRAPS to the host SNMP Community name S...

Page 39: ...ill be used to register the 3G Gateway with the gatekeeper in stead In case both the Authentication ID field and the System Name field are left empty the 3G Gateway can not be registered with the gatekeeper Services The different IP services on the 3G Gateway Telnet SSH HTTP and HTTPS can be disabled independently to prevent access to the system Moreover with Session Time Out a maximum login time ...

Page 40: ... Status Configuring the 3G Gateway Maintenance Upgrade Services Dial Plan Examples Contact Information Maintenance Upgrade TANDBERG 3G Gateway USER GUIDE Maintenance and Upgrade The Maintenance section describes how the system software can be upgraded how new options can be made available via the installation of option keys how the system password can be changed and how the system is restarted ...

Page 41: ...e file are required However for dot release upgrades a Release Key won t be needed To expand software options additional Option keys are required Contact your TANDBERG representative for more details System Information Software Version Shows the currently installed Software version Hardware Serial Number This unique identifier number for the 3G Gateway must be provided when ordering Software Upgra...

Page 42: ...DE Once you have entered the release key in the Release Key field see the previous page and pressed Install Software a new win dow will appear which enables the entry of the software package i e a pkg file to be uploaded For dot release upgrades a Release Key won t be needed Maintenance Upgrading the System Upgrading the System After the pkg file has been selected this will be uploaded into the fl...

Page 43: ...r Add Option key Enter the supplied option keys and press Add Option Password Forgot the password Use the following procedure to set a new password Reboot the 3G Gateway and connect to the 3G Gateway via the serial interface once it has restarted Login with User Name pwrec No password is required You will be prompted for a new password The pwrec account is only active for one minute following a re...

Page 44: ...amples Contact Information Services TANDBERG 3G Gateway USER GUIDE Services On 3G Gateway systems dial plans can be configured with default services Three default services can be distinguished Direct Inwards Dialing Dial Extension IVR TMS Corporate Directory These services can be found under the Service Configuration tab Each default service has a specific number of parameters which can be set by ...

Page 45: ...rvices can be distinguished Direct Inwards Dialing DID Defines a one on one relation between an inbound and an outbound number Dial Extension IVR Also known as Interactive Voice Video Response IVR defines a relation between an inbound number and an interactive service i e a menu via which an outbound service can be connected to The outbound service can be an audio or video service or an externally...

Page 46: ...nted in the Dialplan Configuration overview Net type Inbound call net type either H 324m H 323 SIP or All All means that independent of the net type the call is accepted on a match with the predefined Prefix and Suffix Prefix Number to which the first part of the inbound number bnr is matched The prefix is specified in the dial plan entry The prefix is stripped from the inbound number Suffix Numbe...

Page 47: ... H 324m H 323 or SIP of the outbound call AV mode This mode determines the outbound audio and video call settings It is either Audio Only Audio Video Auto matic no fallback to audio Auto fallback to audio and Auto always fallback to audio In the Audio Only mode a voice call is being setup even when all endpoints support both audio and video capabilities Note that this setting will be overruled in ...

Page 48: ...us page for details Suffix Identical to DID service see the previous page for details Allow forwarding Identical to DID service see the previous page for details Show DTMF Information Screen This is a screen used within the service to draw the attention of the user to activate DTMF tones on its endpoint This screen can be turned on default value or off Media Sources Some of the default Media Sourc...

Page 49: ...efault TMS Corporate Directory Phone Book Service TMS Corporate Directory Argument Details TMS address IP address of Tandberg Management System TMS Allow forwarding Identical to DID service for details see three pages back Show DTMF Information Screen Identical to Dial Extension IVR service Media Sources Some of the default Media Sources like the Welcome Screen the DTMF Information Screen and the ...

Page 50: ...ed Some of these combinations will be discussed in a few examples Example 1 Number plan mapping Entry details Enabled Check Name H 324m H 323 Net Type H 324m Prefix 6789 Suffix Service Direct Inwards Dialing Arguments Net Type H 323 A V Mode Auto fallback to audio Prefix 5 Suffix Use Remainder Yes Allow Forwarding No When dialing the number 67890000 there will be a match with 0000 as the remaining...

Page 51: ...der is set to No DID Dial Plan Examples Example 1 Number plan mapping Entry details Enabled Check Name H 324m H 323 Net Type H 324m Prefix 6789 Suffix Service Direct Inwards Dialing Arguments Net Type H 323 A V Mode Auto fallback to audio Prefix 5 Suffix Use Remainder Yes Allow Forwarding No When dialing the number 67890000 there will be a match with 0000 as the remaining number The H 323 number t...

Page 52: ...ber The 3G Gateway starts to call the endpoint 5 and the Connecting picture and sound are activated When the call is connected audio and video 6 are transmitted through the 3G Gateway SIP to SIP calls and H323 to H323 calls will only go through the 3G Gateway when Allow Forwarding is set to No Dial Extension IVR Examples Example 6 3G to SIP IVR Entry details Enabled Check Name 3G SIP IVR Net type ...

Page 53: ... to a previous stage in the service or even back to the previous service when the phone book is entered via the entry point or dial extension service A menu option is available when text is present next to the respective button In case access to multiple phone books is available the user can select one in the first stage In the second stage either a search string can be entered by the user or you ...

Page 54: ...ade Services Dial Plan Examples Contact Information Contact Information TANDBERG 3G Gateway USER GUIDE Contact Information EUROPEAN HEADQUARTERS Philip Pedersens vei 20 1366 Lysaker Norway Telephone 47 67 125 125 Fax 47 67 125 234 Video 47 67 126 126 E mail tandberg tandberg com U S HEADQUARTERS 1212 Avenue of the Americas 24th Floor New York NY 10036 Telephone 1 212 692 6500 Fax 1 212 692 6501 Vi...

Reviews: