SCSI Identification 

Make sure that the drive unit has the proper SCSI-ID before it is connected to a 
computer system. 

Refer to manuals for host computer and application software to obtain the correct 
ID. For correct mounting of ID-jumpers at the rear of the drive, please refer to 
Figure 3 and Table 1. 

External drives have a thumb-wheel switch to set the SCSI-ID (see Figure 6).  

 

 

Power Connector

SCSI Connector 

Service Connector 

Figure 3  Drive connectors 

 

The factory default drive 
number setting is SCSI ID = 2. 
If the drive has to be set up 
with a different unit number, 
the jumpers (on the Service 
Connector) have to be 
connected according to 
Table 1. 

 

Example: SCSI ID = 3 

 

 

 

SCSI ID=0

 

SCSI ID=1

 

SCSI ID=2

 

SCSI ID=3

 

SCSI ID=4

 

SCSI ID=5

 

SCSI ID=6

SCSI ID=7

 

SCSI ID=8

 

SCSI ID=9

 

 

 

 

 

 

 

Table 1  

Service Connector jumper settings for SCSI 

ID (Dark = Jumper mounted)

 

 

SCSI ID=10

SCSI ID=11

SCSI ID=12

SCSI ID=13

SCSI ID=14

SCSI ID=15

Summary of Contents for 220-420LTO

Page 1: ...Tandberg 220 420LTO Half Height LTO1 and LTO2 Tape Drive Quick Installation Guide Revision 4 February 2006...

Page 2: ...nd at the bottom of the drive Figure 1 Mounting specifications Important Mounting screw requirements Only M3 metric screws must be used for mounting the drive Maximum permitted screw penetration 2 5 m...

Page 3: ...the SCSI ID see Figure 6 Power Connector SCSI Connector Service Connector Figure 3 Drive connectors The factory default drive number setting is SCSI ID 2 If the drive has to be set up with a different...

Page 4: ...e embedded The PC 98 Specification specifies that the termination of the SCSI bus system is a part of the SCSI cable and not a part of the SCSI device As a result termination cannot be turned on or of...

Page 5: ...ON ON ON Cartridge not loaded OFF OFF ON OFF OFF Cartridge loaded no activity ON OFF ON OFF OFF Cartridge loaded activity ON Flashing ON OFF OFF Cleaning OFF Flashing ON OFF Cartridge loading or unlo...

Page 6: ...1 Read Write compatible 609 m 100 GByte 43 26 31 LTO1 2 3 Cleaning Cartridge for LTO1 LTO2 and LTO3 Table 3 Media alternatives External Tabletop Enclosure Figure 6 External tabletop enclosure rear sid...

Page 7: ...tee that this product left our premises defect free If you are not satisfied with the quality of this product please contact your distributor or the nearest Tandberg Data office to have the problem so...

Page 8: ...33 1 39 26 01 01 00800 82632374 Fax 33 1 34 65 02 89 for technical support 00800 07867243 Tandberg Data Asia Pte Ltd 20 Bendemeer Road 04 05 Cyberhub Singapore 339914 Tel 65 6396 0786 Fax 65 6396 0787...

Reviews: