Tandberg Data
StorageLoader
There will be variations of this list. Please refer to your Quick Installation guide
shipped with the StorageLoader.
Note: The StorageLoader contains no cartridges before shipment.
Step 2. Installing the StorageLoader in a Rack
The StorageLoader 1U is designed for use in 19” rack system using 1U of rack
space. The length of the power cord and the SCSI cable may restrict the placement.
Attention:
The StorageLoader is designed to operate in a horizontal position. Do
not attempt to operate the StorageLoader in any other position than horizontally.
Also make sure that:
•
The airflow around the front and back of the StorageLoader is not
obstructed.
•
There is a minimum of 60cm free space in front of the unit to allow the
operator to safely remove the magazines.
•
The display and operator controls are easily accessed.
•
The StorageLoader is away from the floor, and in a clean environment with
temperature within specification.
The Rack Mounting Kit includes the following items:
•
Rail Left Assembly
•
Rail Right Assembly
•
Screw M6x12 (6 pieces)
•
Screw M5x8 (2 pieces)
Recommended mounting tools:
•
Folding rule or tape measure
•
Screwdriver
•
7 mm open-end wrench
Note:
The rails are mounted to the loader during transportation. Before mounting
the rails into the rack, dismount the rails from the loader and remove the spacers
between the rails and the loader.
6
StorageLoader Quick Installation Guide