Tanda TX7210 Installation And Operation Manual Download Page 2

                                                                                                       TX7210 Addressable Single Input/Output Module 

 

 

        Installation & Operation Manual  

                                                                                                                                4050100267-Rev1.6-0916                                                                      

 

 

    TANDA UK  

                                                                                                                                           

Specifications are subject to change without prior notice 

     

 

 
 
Product Safety 
 
 
To prevent severe injury and loss of life or property, read the instruction carefully before installing the 
module to ensure proper and safe operation of the system.  
 
 
 
 

 

European Union directive 

2012/19/EU (WEEE directive): 

Products marked with this symbol cannot be disposed 

of as unsorted municipal waste in the European Union. For proper recycling, return 
this  product  to  your  local  supplier  upon  the  purchase  of  equivalent  new 
equipment, or dispose of it at designated collection points.

  

 
For more information please visit the website at 

www.recyclethis.info

 

 

 
 
 
EN54 Part 18 Compliance 
 
TX7210 Addressable Single Input/output Module complies with the requirements of EN 54-18:2005. 
 

EN54 Standard Conformity Information  
  

 

0832 

17

 

TANDA(UK) LIMTIED 
FOURTH FLOOR 30-31 FURNIVAL STREET LONDON EC4A 
1JQ(Type 1, Option 2 Crosslisting) 
 
TX7210  0832-CPR-F1830  

EN 54-18:2005   

 
 

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TX7210

Page 1: ...TX7210 Addressable Single Input Output Module Installation and Operation Manual TANDA UK Technology Copyright 2015 All right reserved ...

Page 2: ... with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information please visit the website at www recyclethis info EN54 Part 18 Compliance TX7210 Addressable Single Input output Module complies wi...

Page 3: ...rview 4 1 2 Feature and Benefits 4 1 3 Technical Specification 4 2 Installation 5 2 1 Installation Preparation 5 2 2 Installation and Wiring 5 3 Interface Module Configuration 7 3 1 Preparation 7 3 2 Write Addressing 7 3 3 Feedback Mode 8 3 4 Input Check Mode 9 3 5 Output Check Mode 9 3 6 Read Configuration 10 4 General Maintenance 10 5 Troubleshooting Guide 11 Appendix 1 11 Limitation of Interfac...

Page 4: ...that will complement modern building designs and its plug in type assembles make installation and maintenance more convenient to the installer The unit is compatible to the TX7004 Analogue Intelligent Fire Alarm Control Panel produced by single manufacture T A to avoid addressable communication compatibility problem 1 2 Feature and Benefits EN54 18 Compliance Built in MCU processor and digital add...

Page 5: ...voltage rating of the equipment and interface module are compatible 2 2 Installation and Wiring 1 Mount the interface module base on standard one 1 gang electrical back box Follow the arrow mark for the correct position Do not over tighten the screws otherwise the base will twist Use two M4 standard screws 2 Connect the wire in terminal according to the requirement as shown in Figure two 2 to five...

Page 6: ...lly Open Normally Close Relay Output Yes Normally Open Normally Close Normally Close Normally Open Power Limited Output Yes 1 5 3Vdc 24Vdc Figure 2 Input Wiring Details Note Change the parameter Input Check into 3Y Loop Powered Figure 3 Relay Output Wiring Details Loop Powered mostly used Figure 4 Control Output Wiring Details With External Power Supply Figure 5 Control Output with Feedback Signal...

Page 7: ...parately The programmer is packed with twin 1 5V AA battery and cable ready for usage once received It is mandatory for the commissioning personnel to have programmer tool in order to adjust the module conferring to the site situation and environmental requirements Program a unique address number for each device according to the project layout before placing from the Terminal Base Warning Disconne...

Page 8: ...t feedback signal from Input terminal Default setting is External feedback mode 2 Connect the programming cable to Z1 and Z2 terminals Figure 6 Press Power to switch on the unit 3 Switch on the programmer then press button 3 to enter to Configuration mode Figure 10 4 Input the 1 for Self feedback mode or 2 for External feedback mode then press Write to change the setting Figure 11 Note If display ...

Page 9: ... Press Power to switch off the programmer 3 5 Output Check Mode 1 Output Check mode is use to enable voltage monitoring The module will report to the panel in the event of low voltage output cause by open and short circuit occur in the wiring 2 Connect the programming cable to Z1 and Z2 terminals Figure 6 Press Power to switch on the unit 3 Switch on the programmer then press button 3 to enter to ...

Page 10: ...face module it may affect the operation to respond to a fire condition and will void the manufacturer s warranty 4 Use a damp cloth to clean the surface 5 Notify again proper personnel after conducting the maintenance and make sure to enable the interface module and confirm if up and running 6 Perform the maintenance on semi annually or depending on the site conditions 1 Read 2 Write T 3 R W Confi...

Page 11: ...terface Module cannot last forever In order to keep the interface module working in good condition please maintain the equipment continuously according to recommendations from manufacturers and relative nation codes and laws Take specific maintenance measures on the basis of different environments These interface module contains electronic parts Even though it is made to last for a long period of ...

Reviews: