                                                                                                       TX7100 Intelligent Optical Smoke Detector 

 

 

        Installation & Operation Manual  

                                                                                                                               4050100265-Rev1.4-0916                                                                  

 

 

       TANDA UK 

                                                                                                                                           

Specifications are subject to change without prior notice 

1 Introduction  

 

1.1 Overview  

The TX7100 Intelligent Addressable Optical Smoke Detector is the ideal device for most applications, 
due  to  its  spiffing  linear  response  to  a  wide  variety  of  different  types  of  smoke  patterns.  The  unit 
manufactured the sensitivity requirement of EN 54 part 7, European Standard. The unit is aesthetically 
pleasing  with  unobtrusive  design  that  will  complement  modern  building  designs.  The  unit 
incorporates  an  intelligent  processor  that  provides  Algorithm  map,  inbuilt  A/D  converter,  Drift 
compensation, and Self-Diagnosis and History log. 

Secure and speedy communication through the on-board processor enables the detector to make 
its  own  decision,  resulting  in  greater  automation.  In  the  event  of  fire,  the  integral  microprocessor 
analyses the signal according to factors such as signal strength and rate of increase, then confirms 
these  patterns  with  the  pre-programmed  fire  scenarios  and  smoke  patterns,  for  a  faster  and  safer 
response.  Once  it  is  confirmed,  the  LED  indicates  the  sensor  status  and  parallel  sending 
communication  signal  to  the  control  panel.  The  TX7100  detector  is  compatible  to  the  TX7004 
Analogue  Intelligent  Fire  Alarm  Control  Panel,  produced  by  single  manufacture  T&A,  to  avoid 
addressable communication compatibility problem. 

1.2 Feature and Benefits  

 

EN54-7 Compliance 

 

Using microprocessor technology with memory capacity up to 10 events 

 

Analogue sending and digital addressing  

 

Provide real time algorithm to the control panel 

 

Smart linear drift compensation  

 

Onsite adjustable parameter 

 

360 degree visual indicator  

 

Removable chamber against dust and small insect  

 

Ancillary remote indicator output  

 

Aesthetically pleasing design 

1.3 Technical Specification  

 

Listed   

 

 

  

LPCB Certification 

 

Compliance     

 

 

EN54-7:2000 

 

Input Voltage   

 

 

24VDC [16V to 28V] 

 

Current Consumption  Standby  

0.6mA, Alarm: 4mA 

 

Protocol/Addressing    

 

T&A, Value range from 1 to 254 

 

Sensitivity  

 

 

 

As per stipulated standard  

 

Indicator   

 

 

 

Single LED / 360 degree Visual  

 

Material / Colour  

 

 

ABS / White Glossy finishing  

 

Dimension / Height  

 

 

Diameter 99.7 mm / 57 mm 

 

Weight  

 

 

 

145g (with Base), 90g (without Base) 

 

Operating Temperature 

 

-10°C to +50°C 

 

Humidity 

 

  

 

0 to 95% Relative Humidity, Non condensing 

  
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TX7100

Page 1: ...TX7100 Intelligent Addressable Optical Smoke Detector Installation and Operation Manual TANDA UK Technology Copyright 2015 All right reserved ...

Page 2: ... marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information please visit the website at www recyclethis info EN54 Part 7 Compliance TX7100 Intelligent Smoke Detector complies with the...

Page 3: ...troduction 4 1 1 Overview 4 1 2 Feature and Benefits 4 1 3 Technical Specification 4 2 Installation 5 2 1 Installation Preparation 5 2 2 Installation and Wiring 5 3 Detector Configuration 6 3 1 Preparation 6 3 2 Write Addressing 6 3 3 Set LED On Off 6 3 4 Read Configuration 7 4 General Maintenance 7 4 1 Cleaning 8 5 Troubleshooting Guide 8 Appendix 1 9 Limitation of Smoke Detectors 9 ...

Page 4: ...e scenarios and smoke patterns for a faster and safer response Once it is confirmed the LED indicates the sensor status and parallel sending communication signal to the control panel The TX7100 detector is compatible to the TX7004 Analogue Intelligent Fire Alarm Control Panel produced by single manufacture T A to avoid addressable communication compatibility problem 1 2 Feature and Benefits EN54 7...

Page 5: ...take place such kitchens or similar areas where steam and condensation are present Where exhaust fumes are present like car parks Where smoke particles will not be produced by fire Plant Rooms unless full discussions regarding the room contents and status subject to a fire have been made between Client and Manufacturer Boiler and Generator Rooms 2 2 Installation and Wiring 1 Mount the T A standard...

Page 6: ...ng cable to 1 and 6 terminals Figure 3 Press Power to switch on the unit 2 Switch on the programmer then press button Write or number 2 to enter Write Address mode Figure 4 3 Input the desire device address value from 1 to 254 and then press Write to save the new address Figure 5 Note If display Success means the entered address is confirmed If display Fail means failure to program the address Fig...

Page 7: ...ol panel to prevent false alarm 3 Do not attempt to adjust or modify the detector it may affect the ability of the detector to respond to a fire condition and will void the manufacturer s warranty 4 Use a damp cloth to clean the detector Do not use cleaning chemicals that may leave residue on the electronic parts and smoke chamber 5 Notify again proper personnel after conducting the maintenance an...

Page 8: ...ash with running water and ensure it is completely dry 4 Position the chamber and screen by aligning three tiny holes over the sensing component Figure 12 5 Align the LED tube and tabs and gently pushing the cover until it locks into place Figure 12 6 Re install and test the detector 5 Troubleshooting Guide What you notice What it means What to do Address not enrolling The wiring is lose The addre...

Page 9: ...leaking gas improper storage of flammable materials like diluents and other safety hazards arson or children playing with fire The alarm of a smoke detector used in high velocity environment will be delayed due to dilution of smoke by frequent and fast airflow What s more the smoke detector has to be frequently maintained for it is exposed to more dust contamination The smoke detector cannot last ...

Reviews: