Connecting the remaining segment

The after shortening remaining segment with one remaining LED can
be used for instance as a driver´s cab lighting or as lighting for the
passengers´s entrance. The remaining segment should be connected to
the power supply via a series resistor of minimum 1 kOhm. 
When   connecting   it   to   analogue   a.c.   voltage,   you   have   to   connect
additionally   a diode  1N4148 according  to  fig.   7, as the LED  will  be
otherwise damaged after a certain operating duration. 
When connecting it to analogue d.c. voltage, the LED on the remaining
segment will light in one direction of travel only. If you want the LED to
light in both directions of travel, you have to mount a bridge rectifier as
in fig. 8.

7. Check list for troubleshooting

Parts are getting too hot and/or start to smoke.

Disconnect the system from the mains immediately!

Possible cause: one or more connections are soldered  incorrectly.

à

 Check the connections.  

Possible cause: Short circuit. The module is connected to locomotive
or carriage ground.  

à

  Check the connections. A short circuit can

result in irreparable damage.

The LEDs do not light.
Possible   cause:   The   connection   to   the   power   supply   has   been
interrupted. 

à

 Check the connection of the module.

Hotline

If problems with your module occur, our hotline is pleased to help you
(mail address on the last page). 

Repairs 

You can send in a defective  module  for repair (address on the last
page). In case of guarantee the repair is free of charge for you. With
damages not covered by guarantee, the maximum fee for the repair is
50 % of the sales price according to our valid price list. We reserve the
right to reject the repairing of a module when the repair is impossible
for technical or economic reasons. 
Please do not send in modules for repair charged to us. In case of
warranty we will reimburse the forwarding expenses up to the flat rate
we   charge   according   to   our   valid   price   list   for   the   delivery   of   the
product. With repairs not covered by guarantee you have to bear the
expenses for sending back and forth.

Page 17

tams 

elektronik

Summary of Contents for WIB-11

Page 1: ...loi Handleiding WIB 11 Art 53 01110 WIB 12 Art 53 01120 WIB 13 Art 53 01130 Wageninnenbeleuchtung Carraige lighting Eclairage int rieur pour voitures Rijtuiginterieurverlichting tams elektronik n n n...

Page 2: ...in writing from Tams Elektronik GmbH Subject to technical modification Tout droits r serv s en particulier les droits de reproduction et de diffusion ainsi que le traduction Toute duplication ou repro...

Page 3: ...o read the whole manual particularly the chapter on safety instructions and the checklist for trouble shooting You will then know where to take care and how to prevent mistakes which take a lot of eff...

Page 4: ...e and replace them with new ones Electrical hazards Touching powered live components touching conducting components which are live due to malfunction short circuits and connecting the circuit to anoth...

Page 5: ...irections given in the chapter Safety instructions Use a small soldering iron with max 30 Watt Keep the soldering tip clean so the heat of the soldering iron is applied to the solder point effectively...

Page 6: ...tegrated smoothing capacitor is not sufficient you can connect an additional external bridging capacitor and or an external gold cap Dividing and shortening the PCB The 240 mm long PCB with 8 LEDs can...

Page 7: ...e places shown in fig 1 Caution Pay attention not to damage the connection pads or the parts on the PCB when sawing You can divide or shorten the PCB as follows division into 2 parts with 4 LEDs each...

Page 8: ...he necessary series resistors are integrated on the PCB Solder the LEDs according to fig 6 to the connecting points LED and LED Please note It is not possible to use electric bulbs instead of LEDs as...

Page 9: ...connections Possible cause Short circuit The module is connected to locomotive or carriage ground Check the connections A short circuit can result in irreparable damage The LEDs do not light Possible...

Page 10: ...manual In addition the guarantee claim is excluded in the following cases if arbitrary changes in the circuit are made if repair attempts have failed with a ready built module or device if damaged by...

Page 11: ...WIB 11 WIB 12 WIB 13 WIB 11 WIB 12 WIB 13 I I t a m s e l e k t r o n i k...

Page 12: ...WIB 11 WIB 12 WIB 13 WIB 11 WIB 12 WIB 13 II II t a m s e l e k t r o n i k...

Page 13: ...tie en tips n n http www tams online de n n n Garantie und Service Warranty and service Garantie et service Garantie en service n n Tams Elektronik GmbH n Fuhrberger Stra e 4 DE 30625 Hannover fon 49...

Reviews: