5. Software Update
Your SniffControl is a state-of-the-art product, which is constantly improved and adapted to
occurring changes. To benefit from this development, you can update the MasterControl to the
newest software version.
Diconnect
all
external control devices from the
EasyNet – including the SniffControl you want to
update.
Unsrew the cover from the housing. Then bypass
the pins of the pin-type strips at the SniffControl
according to the adjoining diagram (e.g. with the
added jumpers) and restore the connection from
SniffControl to the EasyNet.
Next select the menu point "Software Update" at
your MasterControl and confirm your input with
# / ok. The MasterControl will then display in
the second line "...Download..."
Now please connect the MasterControl to your PC
and execute the update application.
Please note: Always connect the MasterControl to your PC before executing the update
application. Otherwise your PC might have difficulties detecting the interface.
Follow the instructions of the update application.
6. Technical Specifications
Power supply for SniffControl:
via EasyNet
Power consumption (without consumer):
approx. 100 mA
Interfaces:
EasyNet (2 x RJ-45)
Track connection
Protection:
IP 00
Ambient temperature while operating:
0 - + 60 °C
Ambient temperature while not operating:
-10 bis + 80 °C
Maximum humidity:
max. 85 %
Dimensions (including housing)
approx. 100 x 90 x 35 mm
Weight including housing
approx 190 g