tams elektronik SniffControl Manual Download Page 6

English

SniffControl

Page 6

4. Operation with the SniffControl

As a precondition for using the SniffControl in the digital controller EasyControl all connected
devices (MasterControl and additional EasyControl devices) must have the software version
V1.4.5s or higher. If not so, the SniffControl will not work properly or not at all. If necessary,
perfom a software update for your MasterControl and all EasyControl devices.
Before you can send control and switching commands from an external central unit into the
EasyNet you have to make the following connections:

§

 

SniffControl – track connection of external central unit

§

 

SniffControl – EasyNet connection of the MasterControl

Sending switching and control commands

Enter the control and switching commands according to the instructions for the external central
unit. Please note that locomotive commands will be transferred as well in Motorola as in DCC
format, but points commands only in DCC format.
The digital format used by the external central unit and the digital format in which the locomotive
decoders receive data must not be the same, as the commands are not sent directly from the
external central unit to the decoders but via the MasterConrol. For that reason you can

§

 

control locomotive decoder with a DCC decoder with pure Motorola central units (or visa
versa)

§

 

with digital central units sending only 14 speed levels control locomotive decoders set to 28 or
128 speed levels

Faults during operation

In standard operation the LED on the SniffControl is switched off. It lights up as soon as a fault in
data transfer occurs, that is when a command entered at the external central unit could not be
sent. As soon as the fault has been resolved the LEDs stops lighting.
The LED flashes when accessing more than 15 locomotive adresses. In this case you have to
perform a reset on your external central unit or switch off the central unit for a short time. This
deletes all by then accessed locomotive addresses from the central unit´s refresh (the memory).
In normal case the LED stops flashing after accessing a new locomotive address.
In particular cases it may occur the LED does not stop flashing after this procedure. Then cut the
connection to the MasterControl (the patch cable) or switch off the MasterControl for a short time.
N.B.: In this case it is not sufficient to perform a reset on the MasterControl.

Summary of Contents for SniffControl

Page 1: ...SniffControl Adapter for connecting digital central units Digitalzentralen to the digital control EasyControl Item no 40 01507 01 Manual...

Page 2: ...sse 6 46244 Bottrop n n n Information and tips www tams online de Warranty and service Tams Elektronik GmbH Rupsteinstra e 10 D 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail modell...

Page 3: ...the SniffControl does not transfer points commands sent in Motorola format it is impossible to use the keyboard 6040 or the memory 6043 with the SniffControl M rklin Mobile Station N B When connecting...

Page 4: ...ot supported by the SniffControl 2 Getting started Contents SniffControl two short circuit jumpers patch cable RJ45 this manual Saftey instructions The SniffControl should only be used in digital mode...

Page 5: ...ffControl to the EasyNet connection of the MasterControl Use the inclosed patch cable or a comercially available patch cable of any length Hint When the EasyNet connection of the MasterControl is in u...

Page 6: ...e the same as the commands are not sent directly from the external central unit to the decoders but via the MasterConrol For that reason you can control locomotive decoder with a DCC decoder with pure...

Page 7: ...Update at your MasterControl and confirm your input with ok The MasterControl will then display in the second line Download Now please connect the MasterControl to your PC and execute the update appl...

Page 8: ...ilt module Conditions of warranty This product carries a two year garantee covering material defect and fabrication errors We also guarantee the adherence to the product specifications as long as the...

Reviews: