Transmission of commands for vehicle decoders

Unlike in connection with the Märklin**-Control Unit, the number of locomotive addresses is
not generally limited to 80. With the Control 80F driver's desk and the additional device Infra
Control 80F, 99 locomotive addresses can be controlled each. Due to the design, only 80
locomotive   addresses   can   be   transmitted   with   the   Control   80   driving   desk,   even   when
connected to the mControl. 
The commands that are entered at the Märklin** devices are not sent directly but from the
EasyControl central unit to the vehicle decoders. Therefore, compared to the use together
with the Märklin**-Control Unit, some functionalities change : 

You can control vehicles with Motorola as well as with DCC decoders (address range: 1 to
80 or 1 to 99).  

You can also control vehicle decoders that are set to 27, 28 or 128 speed steps. The speed
steps are converted internally by the mControl. 

You can switch the functions F0 (function) to F4 as usual. Other functions (from F5), which
were switched from other (non-Märklin**) control units, retain their position (on or off)
when the control of a decoder is taken over by a Märklin** control unit.  

Transmission of commands for accessory decoders

The   number   of   turnout   addresses   is   limited   by   the   input   possibilities   of   the   respective
Märklin** devices. Since the commands that are entered at the Märklin** devices are not sent
directly but by the EasyControl central unit to the accessory decoders, decoders that react to
Motorola commands as well as decoders that react to DCC commands can be controlled. 

Programming decoders

It is not possible to access and change the data in the locomotive database of the EasyControl
control   unit   from   the   Märklin**   devices.   The   mControl   does   not   transmit   programming
commands,   therefore   e.g.   the   main   track   programming   (POM)   is   not   possible   from   the
Märklin** devices.

Connection of a PC

A PC that is to be integrated into the EasyControl digital control must be connected directly to
the EasyControl central unit, as PC interfaces (e.g. 6050 or 6051) are not supported by the
mControl. 

5

Summary of Contents for mControl 40-01607

Page 1: ...Manual mControl Adapter for the integration of additional devices for M rklin 6020 and 6021 into the EasyControl digital system Item number 40 01607 tams elektronik n n n...

Page 2: ...ormity 15 8 3 Declarations on the WEEE Directive 15 Version 2 0 12 2021 Tams Elektronik GmbH All rights reserved in particular the right of reproduction distribution and translation Copies reproductio...

Page 3: ...nd non observance of the instructions can lead to incalculable hazards Prevent these dangers by carrying out the following measures Use the mControl unit only in closed clean and dry rooms Avoid humid...

Page 4: ...efore also required The mControl receives the control and switching commands sent by the M rklin control units keyboards controls translates them into control and switching commands for the EasyNet da...

Page 5: ...nctions F0 function to F4 as usual Other functions from F5 which were switched from other non M rklin control units retain their position on or off when the control of a decoder is taken over by a M r...

Page 6: ...and or Memory 6043 Make the connections in the same way as the corresponding connections to the M rklin Control Unit Power supply Power Plug in power supply unit not included in the scope of delivery...

Page 7: ...onnections to the EasyNet This may cause irreparable damage to the central unit Connecting several external control units or adapters to the EasyNet You can connect a total of up to 64 external contro...

Page 8: ...rklin devices You can also control DCC decoders as the commands are not sent directly from the M rklin devices but from the EasyControl central unit to the decoders It is also possible to control vehi...

Page 9: ...ly charge the shipping costs for the return according to our valid price list 5 1 Starting the software update First download the firmware i e the software that controls the mControl from the homepage...

Page 10: ...o the instructions of the programme 5 3 Update with the RedBox To update with the RedBox you need the software CV Navi which you can download free of charge from our homepage Please note Always connec...

Page 11: ...s connected to your mc via the EasyNet interface Section of the Update interface of the mc toolbox Click the Browse button and select the file with the current firmware that you have saved on your PC...

Page 12: ...ical hotline will help you telephone number and e mail address on the last page Repairs You can send us a defective circuit for repair address on the last page In the event of a warranty or guarantee...

Page 13: ...urrent consumption without consumer approx 100 mA Schutz Predection IP 20 Meaning Predected against solid foreign bodies with a diameter 12 5 mm and access with a finger No predection against water En...

Page 14: ...nd perfect condition of the components as well as a function of the components in accordance with the characteristic values in uninstalled condition We guarantee compliance with the technical data if...

Page 15: ...bject to the requirements of the EU Directive 2012 19 EC on Waste Electrical and Electronic Equipment WEEE i e the manufacturer distributor or seller of the product must contribute to the proper dispo...

Page 16: ...ils Meer informatie en tips n n http www tams online de n n n n Garantie und Service Warranty and service Garantie et service Garantie en service n n Tams Elektronik GmbH n Fuhrberger Stra e 4 DE 3062...

Reviews: