LD-G-3 / LD-W-3
English
Page 27
The operating voltage of the locomotive motor at speed level 14 is set
by adjusting the maximum velocity. The adjustment should be such that
the locomotive reaches the desired maximum speed at speed level 14.
The operating voltages of the locomotive motor at speed levels 2 to 13
are linearly interpolated.
Shunting gear
The auxiliary function F4 allows you to switch into the shunting gear
mode. In the shunting gear mode the velocity of all speed levels is
reduced to ca. 50 % compared to the standard velocity.
Acceleration and brake delay
14 different steps are available for the acceleration and brake delay.
The acceleration and brake delay can be switched off via the auxiliary
function F3.
Function lighting
The lighting can be switched on and off according to the direction of
travel from the central unit via the function "function".
Online-programming
The address and the driving characteristics can be programmed online.
This means:
§
In order to start the programming mode and to set the desired
(new) address, it is not necessary to enter the present address.
§
While programming the driving characteristics (starting and
maximum velocity, acceleration and brake delay) the locomotive is
running. By operating the speed knob the driving characteristics are
altered. As soon as these are set as desired, they can be saved
directly (online).
Restrictions in Motorola I format
The auxiliary functions F3 and F4 are not available in Motorola I format.
Summary of Contents for LD-G-3