5. Checklist for troubleshooting and error correction
Warning:
If you notice a strong heat development, immediately disconnect the
connection to the supply voltage.
Fire hazard!
Possible causes:
One or more connections are faulty.
à
Check the connections.
The current consumption of the vehicles in the terminal loop exceeds 3 A.
à
Reduce the
current consumption.
The module is defective.
à
Send the loop module in for inspection.
Short circuit when entering the transition areas
Possible causes:
The connections to the points W1 and W3 have been connected the wrong way. For that
reason the polarity within the terminal loop does not correspond to the actual position of
points.
Interchange the connections to the points W1 and W3.
The connections to the rails differ from the connections diagram. Check the connections
1 to 6 and correct them if necessary.
The points have been set manually (bypassing the KSM-4). You should use the push-
buttons or the integrated points decoder to set the points instead.
Stop of the locomotive when entering the transition areas
Possible causes:
One or several connections to the rails have been interrupted. Check the connections 1
to 6 and correct them if necessary.
12 | Checklist for troubleshooting and error correction