FD-R
Basic
English
Page 51
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Extended
address
17
04
192 ... 255
(192)
18
05
0 ... 255
(255)
Only for DCC format. Most
central units permit entering
extended addresses directly.
The CVs # 17, 18 and 29 are
set automatically to the
proper values.
Consistadresse 19
06
1 ... 127
(0)
= 2
nd
adress
In DCC format only!
Configuration
29
07
0 ... 64
Numerical value
*
data 1
(14)
Direction "Standard"
0
Reverse direction
1
14 speed levels
0
28 or 128 speed levels
2
Analoge recognition off
0
Analoge recognition on
4
RailCom off
0
RailCom on
8
Basic addresses
0
Not for MM mode: Extended addresses
32
Example: CV#29 = 0.
à
Direction = "Standard". 14 speed levels. RailCom = "off".
Automatic analogue recognition = "off". Basic addresses.
Example: CV#29 = 46.
à
Direction = "Standard". 28 or 128 speed levels in DCC-
mode. Automatic analogue recognition = "on". RailCom = "on". Extended
Addresses.
Tip: If the use of extended addresses is activated in CV#29, the decoder does
not react to signals in Motorola format!
Tip: In order to program the function decoder area, you have to set RailCom to
"off". Programming the data for the RailCom area is done in a separate step with
RailCom set to "on".