Booster B-6
t
a
ms elektronik
Function
Input
value for
CV 7
Setting / Comment
Display
Switching the
watchdog on and off
with DCC turnout
command
Default value:
–- / inactive
76
→ The RGB LEDs flash white.
Switch to switch turnouts on your digital
control. Set the desired turnout address
and enter a turnout setting command for
this address ("straight ahead" for "active"
or "branch" for "inactive"). The turnout
address and operating status are now set.
Autostart
Default value: active
80
Autostart active
S1
81
Autostart inactive
S0
Brightness of the RGB
LEDs
Default value: 3
90
1 = minimum brightness
1
91 … 97
2 … 8
2
98
9 = maximum brightness
9
Restart time after
5 short-circuits
Default value:
60 seconds
100
0 sec.
00
101
10 sec.
10
102
20 sec.
20
103 … 108 30 ... 80 sec.
30 … 80
109
90 sec.
90
Time until the short-
circuit switch-off
responds
(Short-circuit sensitivity)
Default value: 100 ms
110
20 ms
02
111
40 ms
04
112
60 ms
06
113 … 118 80 … 180 ms
08 … 18
119
200 ms
20
Max. duration of
inrush current
("Inrush time")
Default value:
500 ms
120
50 ms
05
121
100 ms
10
122
150 ms
15
123 … 128 200 … 450 ms
20 … 45
129
500 ms
50
28 | Settings / Configuration