![tams elektronik 53-03110 Manual Download Page 17](http://html1.mh-extra.com/html/tams-elektronik/53-03110/53-03110_manual_816273017.webp)
WIB-31 | WIB-32 | WIB-33
English
Function keys for switching AUX2
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
AUX2
122 45
1 ... 255 (1) F0
1
It is possible to activate the function with several
function keys.
Factory settings: AUX2 is activated with F0.
F1
2
F2
4
F3
8
F4
16
F5
32
F6
64
F7
128
Dependant on the direction of motion of the LEDs and the
outputs
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
LED1 | LED2
53
25
0, 1, 2, 16,
17, 18, 32,
33, 34 (0)
LED 1, 3, 5 or 7 off
at backward motion
1
LED3 | LED4
54
26
0, 1, 2, 16,
17, 18, 32,
33, 34 (0)
LED 1, 3, 5 or 7 off at
forward motion
2
LED5 | LED6
55
27
0, 1, 2, 16,
17, 18, 32,
33, 34 (0)
LED 2, 4, 6 or 8 off
at backward motion
16
LED7 | LED8
56
28
0, 1, 2, 16,
17, 18, 32,
33, 34 (0)
LED 2, 4, 6 or 8 off
at forward motion
32
AUX1 | AUX2
57
29
0, 1, 2, 16,
17, 18, 32,
33, 34 (18)
AUX1 or AUX3 off
at backward motion
1
AUX3
58
30
0, 1, 2 (0)
AUX1 or AUX3 off
at forward motion
2
AUX2 off
at backward motion
16
AUX2 off
at forward motion
32
Factory settings: AUX1 switched off at forward motion, AUX2 switched off at backward motion
(CV#57 = 2 + 16 = 18)
Dimming of the LEDs and the outputs
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
LED1 | LED2
59
31
0 ... 255
(255)
= Reducing the voltage
applied to the output A.
1= minimum voltage
255 = maximum voltage
LED3 | LED4
60
32
0 ... 255
(255)
LED5 | LED6
61
33
0 ... 255
(255)
LED7 | LED8
62
34
0 ... 255
(255)
AUX2 | AUX1
63
35
0 ... 255
(255)
AUX3
64
36
0 ... 255
(255)
You can choose a value between 0 and 15 for each output. Enter the value directly for the odd
LEDs and outputs, for the even LEDs and outputs multiply the value by 16.
Example: For LED1 value "14" and for LED2 value "2"
à
Input value in CV#59: 14 + 2x16 = 46.
With outputs for which a fluorescent tube simulation or a random light have been
programmed, the settings in CV ##59 to 64 have no effect.