![tams elektronik 22-01-090 Manual Download Page 19](http://html1.mh-extra.com/html/tams-elektronik/22-01-090/22-01-090_manual_816281019.webp)
LD-G-20
English
Page 41
CV-name
CV-
no.
Input value /
(State of
delivery)
Remarks
Numerical value *
2
Load control active
1
Emergency stop at
change of direction
2
Emergency stop at F1
4
Shunting gear mode at F1
8
Shunting gear mode at F2 16
Shunting gear mode at F3 32
Configuration
data 2
49
0 ... 127
(1)
Shunting gear mode at F4 64
Dimming of
the outputs::
X5
50
X6
51
0 ... 63
(63)
= The voltage that is applied to
the output.
The value "1" corresponds to
the minimum, „63“ to the
maximum voltage.
Parameter of
load control KP
54
0 ... 255
(96)
= Proportional component of
the load control.
Assignment
0 ... 31
Numerical value *
2
F0 – F4 to
Operation with:
the outputs:
---
0
X5
55
(16)
function key F1
1
X6
56
(16)
function key F2
2
function key F3
4
function key F4
8
function key F0
16