![tams elektronik 22-01-090 Manual Download Page 18](http://html1.mh-extra.com/html/tams-elektronik/22-01-090/22-01-090_manual_816281018.webp)
English
LD-G-20
Page 40
CV-name
CV-
no.
Input value /
(State of
delivery)
Remarks
Maximum
voltage
5
0 ... 255
(0)
= The voltage to be output to the
motor at the highest speed level.
The value "2" corresponds to
0,8 %, the value "255" to
100 % of the max. voltage.
Version
7
---
Read only!
Manufacturer
8
(62)
Read only!
Reset
8
0 ... 255
Any value restores the settings
in state of delivery.
Extended
adress
17
18
1 ... 10239
(-)
Numerical value *
2
Direction "standard"
0
Reverse direction
1
14 speed levels
0
28 or 128 speed levels
2
Analoge recognition off
0
Analoge recognition on
4
Linear velocity characteristic 0
Alternative
velocity characteristic
16
Basic adress
0
Configuration
data 1
29
(6)
Extended adress
32
Assignment
0 ... 15
Numerical value
*
2
F5 – F8 to
(0)
Operation with:
the outputs:
---
0
X5
39
function key F5
1
X6
40
function key F6
2
function key F7
4
function key F8
8