background image

Installation Manual

Ground Roof

Mount Series

[email protected]       

1-800-819-7236 Ext 556

  Page 2

Components List

The following parts are included with the GR mounts 

Part #

Description

UNI-GR/90

UNI-GR/130

51-0627-003

Channel Connector

2

2

51-0545-001

Panel Support Channel - 45-inch

4

51-0565-001

Panel Support Channel - 65-inch

4

51-0546-000

Inner Brace Channel - 46-inch

2

2

51-0546-001

Outer Brace Channel - 46-inch

2

2

51-6000-003

U-Foot

4

4

51-6000-004

Backing Plate

4

4

29-5001-100

Mount Assembly Hardware – 5/16-inch

1

1

29-5001-0GR

Module Mounting Hardware – ¼-inch

4

4

Inner\Outer Brace channels         

Channel Connector

Panel support Channel

U-Foot and Backing Plate

Summary of Contents for UNI-GR/130

Page 1: ...of Mount Series Installation Manual 2022 Edition UNI GR MAN v3 Formodels Panel Support length UNI GR 90 90 UNI GR 130 130 The picture at rtight shows the rear view of 2 of the UNI GR mounts connected with the optional intertie kit ...

Page 2: ...tion 10 InstallerResponsibility 11 Warranty Information 11 Introduction The Universal Ground Roof Mount is a simple and universal mounting solution up to 3 solar panels With its user adjustable angle settings the Ground Roof Mount can support installations in a wide range of locations as a standalone or multiple mounts intertied in rows Quantities of panels supported vary by panel widths Customer ...

Page 3: ...onnector 2 2 51 0545 001 Panel Support Channel 45 inch 4 51 0565 001 Panel Support Channel 65 inch 4 51 0546 000 Inner Brace Channel 46 inch 2 2 51 0546 001 Outer Brace Channel 46 inch 2 2 51 6000 003 U Foot 4 4 51 6000 004 Backing Plate 4 4 29 5001 100 Mount Assembly Hardware 5 16 inch 1 1 29 5001 0GR Module Mounting Hardware inch 4 4 Inner Outer Brace channels Channel Connector Panel support Cha...

Page 4: ...ct Panel Support Channels A Slide the 10 connector halfway into the end of the one of the panel support and install the 5 16 hardware Torque to 132 in lbs repeat with the second panel support to achieve the overall panel support length B UNI GR 90 uses two 45 panel support channels UNI GR 130 uses two 65 panel support channels ...

Page 5: ...urface measure the center to center distance between the U feet to determine the front to rear spacing for the footing B Keep the rear brace assembled at the overlap determined in prior operation preassemble the second pair and set aside C For the side to side footing of both A frames the center to center spacing is equal to the center to center distance of the mounting holes on the PV module you ...

Page 6: ...e distance from the top of the module mounting rail to the hole used to connect the back leg See the diagrams on Page 4 UNI GR 90 UNI GR 130 A ANGLE Û Û Û 36 A ANGLE Û Û Û 32 C OVERLAP 16 28 40 44 C OVERLAP 10 22 34 44 D DISTANCE 15 15 15 15 D DISTANCE 41 41 41 41 E FOOT SPACING 78 78 78 78 E FOOT SPACING 75 75 75 75 UNI GR 90 UNI GR 130 A ANGLE 55 Û Û Û 25 A ANGLE 45 Û Û 20 C OVERLAP 6 12 24 38 4...

Page 7: ...Installation Manual Ground Roof Mount Series support tamaracksolar com 1 800 819 7236 Ext 556 Page 6 Step 3 Foot attaching options Use Galvanized or Stainless Steel Hardware See Suggestions below ...

Page 8: ...nd supports parallel C Align mounting holes on the panels with the slots on the panel supports allow Approximately 1 4 to 1 in between PV modules and leave any available left over support length at the bottom of the array for ground clearance to allow for vegetation management D Secure with 5 16 hardware and torque to 132 in lbs if the mounting holes on the solar panels are large enough If the pan...

Page 9: ...ootings align the feet east west and north south and torque 3 8 16 galvanized hardware to 16 ft Lbs Concrete footings shown Space between mounts Step 2 Attach Preassembled rear braces to footings A Loosely attach the pre assembled rear brace to the rear footings pre assembled from the prior angle determination step The outer leg is attached to the foot Lay back away from the front for next step ...

Page 10: ... to footings A Loosely attach one end of the Panel assembly to the U feet on the footings Step 4 Attach rear braces to panel supports A Tilt up the array and the rear braces and bolt the rear leg into the hole chosen at the distance on step 2 of Determine foot spacing operation or the general spec chart B Torque all locations to 132 in lbs ...

Page 11: ...unt This brace is adjustable from 18 25 to 32 and can be used with solar panels that have mounting holes that at between 7 and 15 from the end of the modules A Loosely connect the inner and outer intertie channels with the 5 16 bolt lock washer flat washer and hex nut B Place the intertie as shown about midway between the rear brace connection and the end of the panel support channels slide the ch...

Page 12: ...is VOID if the practices specified by AAMA 609 610 02 Cleaning and Maintenance for Architecturally Finished Aluminum www aamanet org are not followed by Purchaser for Tamarack Solar s aluminum based products The warranty covers the replacement cost of parts to repair the product to proper working condition Transportation and incidental costs associated with warranty items are not reimbursable The ...