SETUP SCREEN - OVERVIEW
1.
DISPLAY
1.1.ENGINE
TYPE is the selected engine profile to be controlled
1.1.1.
CAT 3.4B
1.1.2.
DEUTZ TCD2.9
1.1.3.
JOHN DEERE
All temperatures displayed in Fahrenheit
1.2.LOW TEMP SETPOINT is the LOW temperature setting.
1.3.MID TEMP SETPOINT is the MEDIUM temperature setting.
1.4.HIGH TEMP SETPOINT is the HIGH temperature setting.
1.5.HIGH IDLE ENGINE TEMP is the minimum “warm up” temperature the Engine
must reach before proceeding to High Idle startup.
1.5.1.
NOTE:
High Idle setting is 1800 RPM
1.6.DUCT OVER TEMP is the max allowable temperature within the Duct before the
machine will perform a commanded shutdown sequence.
1.7.LOW IDLE ENGINE TEMP is the minimum “cool down” temperature the Engine
should reach before proceeding to Low Idle shutdown.
1.7.1.
NOTE:
If this temperature is not reached within 3min the Engine will
proceed to Low Idle and shutdown.
1.8.BLOWER 1 DELAY is the time delay after engine is started to engage the Blower
Motor. Display is in seconds.