![Tamarack Industries Heat King HK300B Operation Manual Download Page 38](http://html1.mh-extra.com/html/tamarack-industries/heat-king-hk300b/heat-king-hk300b_operation-manual_815707038.webp)
38
Troubleshooting
The Tamarack Construction Heat King is a self-contained glycol heating system that can be used to thaw
frozen ground or maintain a work area at a constant temperature. It is a simple system that requires minimal
maintenance.
In the following trouble shooting section, we have listed many of the problems, causes and solutions to the
problems which you may encounter.
If you encounter a problem that is difficult to solve, even after having read through this trouble shooting sec
-
tion, please contact your authorized dealer, distributor or the factory. Before you call, please have this Opera-
tor’s Manual and the serial number from your machine ready.
PROBLEM
CAUSE
SOLUTION
Burners won’t start.
No fuel.
Fill the fuel tank.
No power.
Plug machine in and turn on.
Breaker tripped. Reset breaker.
Low glycol.
Fill glycol reservoir.
Switch off.
Pull out Emergency Stop switch.
NOTE: For the burners to be able to fire, three conditions must be met.
1) The Pressure switch on the circulation loop must see pressure. (gray plastic box on circ pump)
2) The low glycol sensor must sense glycol. (blue box on glycol tank)
3) The aquastat temperature has to allow the call for heat, by being below 230°F. This condition
would be very rare, and should only trip off if there is not enough flow through the coil or the burner is burning
too hot. (gray box on coil discharge beside exhaust)
Buners give off black smoke. Wrong fuel/air mixture.
Reset air mixture.
Fouled burner.
Clean burners.
Plugged fuel filter(s).
Change filter(s).
Reel won't move.
No power.
Turn power on.
Reset circuit breaker.