![Tamarack Industries Heat King HK300B Operation Manual Download Page 21](http://html1.mh-extra.com/html/tamarack-industries/heat-king-hk300b/heat-king-hk300b_operation-manual_815707021.webp)
21
Operating Temperature
Selection
The Heat King is designed with an
electronic programmable tempera-
ture controller. The temperature
controller will measure the tempera-
ture of the reservoir and will then
control the burner to maintain a set
temperature range. The unit comes
with a factory set operating tempera-
ture of 180°F with a 10°F (5.5°C)
temperature drop before the burner
will fire again.
The operating temperature can be
set to operate at any temperature
up to 180°F (82°C) by following this
procedure:
a. Press 'SET' for 1 second. The set
value (desired temperature) will
then start flashing after a few mo
-
ments.
b. Use the UP and DOWN buttons
on the right of the display to in-
crease or decrease the value.
c. Press 'SET' to confirm the select
-
ed temperature press as the new
set point.
*
The return temperature is only a
display and does not need to be
set.
SUPPLY TEMPERATURE CONTROLLER