TP-60BA (Rev 2.2)
- 35 -
TALON TECH CO. LTD.
3. As per [PIC 2], install the touch pad on the equipment.
4. The panel type can be changed up to the equipment
’
s position.
8-4-4 Suggested Recipe Setting Value (PR viscosity: 1,800cP)
Volume(g)
Data Input
Dispense/Time
Data Input
Reload/Time
Data Input
1
100
2.5
250
17
1700
2
200
3.5
350
18
1800
3
300
4.5
450
19
1900
4
400
5.5
550
20
2000
5
500
6.5
650
21
2100
6
600
7.5
750
22
2200
7
700
8.5
850
23
2300
8
800
9.5
950
24
2400
9
900
10.5
1050
25
2500
10
1000
11.5
1150
26
2600
Dispense time(D/T) formula : Volume(g)+1.5=D/T => ex) 18+1.5=19.5
Reload time formula : Volume(g)+16=R/T => ex) 18+16=34
※
The above data is based on 1,800cP. It is supposed to be changed upon cP.
Suggested setting value as per time