TP-40BA (Rev 1.0)
- 32 -
TALON TECH CO. LTD.
9-2 Pump Dimensions
9-2-1 Front View
9-2-2 Side View
Page 1: ...TP 40BA Rev 1 0 TALON TECH CO LTD Excellent Dispense Volume Reliability Pump Controller Built in type TALON TECH CO LTD MODEL TP 40BA...
Page 2: ...ection Board Name Explanation 7 4 Wiring Signal Interface 8 4 1 Track I O Signal Timing Chart 8 4 2 Track Pin Assign 9 4 3 COMM ETC Pin Assign 9 4 4 Touch Pad Pin Assign 10 4 5 Dispense Trigger Select...
Page 3: ...Pump Parts Dis Assembly 29 8 1 1 Degas Pump Cover Dis Assembly 29 8 1 2 Buffer Tank Empty Sensor s Sensitivity Adjustment 29 8 1 3 Driving Shaft Condition Check Grease up on Ball Screw 30 9 Recommende...
Page 4: ...A pump Be careful to use the pump by following this manual or Talon Tech s acceptance Or other defects should be paid even under the warranty period Features Merits 1 All the PR contacting points are...
Page 5: ...Suck Back Rate 0 1cc sec 7 0cc sec Dispense Volume Resolution 0 0025cc Dispense Repeatability 0 02 2 2cp 23 Viscosity Max 150cp Pump Driving Type DC Servo Motor 1 Cycle Step 4 Dispense Step Suck Back...
Page 6: ...inish Signal To Track M C 2 Suck Back V V control Sol V V Signal 3 On Pump Operation Error Alarm Signal 4 Outside Communication RS422 2 2 Touch Pad ITEM SPEC REMARKS Main CPU 32Bit ARM920T Ram 64Mb OS...
Page 7: ...TP 40BA Rev 1 0 4 TALON TECH CO LTD 3 1 Pump In Exterior Names System In Exterior Names 3 Degas Pump Dispense Pump Buffer Tank Air Sol Block Ass y Main Control Board Cylinder...
Page 8: ...n 2 channel Sol Block Buffer Tank Bubble removal and buffering function of about 30cc PR Degas Pump Air Cylinder Type Pump for charging PR into Buffer Tank Dispense Pump Pump for the accurate PR dispe...
Page 9: ...to touch pad D SUB Male 15P Air In Main air supply outlet to operate degas pump air valve 6 Air Tube 3 2 Touch Pad Exterior Names 3 2 1 Touch Pad Name Explanation Touch Panel Touching area Power In To...
Page 10: ...ion Connector Molex 6P Main COM In case the machine controls the pump use this Communication Connector Molex 4P Switching I O Switching Connector to exchange Touch Pad Main COM s communication Molex 5...
Page 11: ...TP 40BA Rev 1 0 8 TALON TECH CO LTD 4 1 Track I O Signal Timing Chart Wiring Signal Interface 4...
Page 12: ...P Output Alarm Pump Stop 9 ALARM WARNING Output Alarm Pump works 10 TRACK_HOME Output Pump Ready 11 TRACK_END Output Pump Dispense End 12 TRACK GND Output Track GND 13 TRACK VCC Input Track Power 24V...
Page 13: ...Supply Power 9 Not Use Not Use Touch Pad Power Pin Assign 3P Pin NO Signal Name I O Description 1 MC 24V Input Touch Pad Supply Power 2 Not Use Not Use 3 MC_GND Input Touch Pad Supply Power Touch Pad...
Page 14: ...0BA Rev 1 0 11 TALON TECH CO LTD 4 5 Dispense Trigger Select 0 Trigger Off 1 Trigger On Recipe Select Start1 1 Start2 2 Start3 3 Remark 1 1 0 0 2 0 1 0 3 1 1 0 4 0 0 1 Cycle Recipe 5 1 0 1 6 0 1 1 7 1...
Page 15: ...ON TECH CO LTD 5 1 Track Cable 5 2 COM Cable 5 3 Touch Pad Cable External Cable Length 5 Cable for Touch Pad in Use Cable for Touch Pad in no Use Touch Pad Power Cable Touch Pad Main COM Cable Touch P...
Page 16: ...hich is not searched cannot be chosen 6 1 2 Pump Condition Indicate In Use Dispense Ready Purge Mode Not Connect 6 1 3 Select Function When ID is chosen the above screen is shown ESC go to the previou...
Page 17: ...you want to go in and touch Ent At this time Recipe Data is automatically shown on the screen And you can input the data that you want and touch set button for setting Count is only for 4th recipe cyc...
Page 18: ...sensor s setting So it becomes Yes on normal situation In case of No degas doesn t work even if the buffer tank is empty Degas count can be set from 0 999 Degas Run Degas Stop has the function to make...
Page 19: ...int Mode Change Pump Mode to Maint Run Mode Change Pump Mode to Run Pump Reset Reset Pump It means Pump Restart not Data Reset Error Mark Stop Error Setting Discuss with Talon Tech ID Setting For ID S...
Page 20: ...ch Ent In case of no response from pump message of mode keeps showing Pump reset works right after input password It goes to the initial screen same as power off and on It takes about 20sec Error Stat...
Page 21: ...calibration value If there is the differences between the real value and the setting value set the calibration value higher or lower at the standard 100 6 2 Example 6 2 1 Dispense If you want to dispe...
Page 22: ...Cycle only works the case of using Start Cycle Keep touching Stop Cycle button 6 2 2 Recipe Choose the recipe and touch Ent button The chosen recipe data is automatically read from the pump Set the r...
Page 23: ...Rev 1 0 20 TALON TECH CO LTD 6 2 3 ID Setting Choose ID which you want to change from 11 44 ID consists of 2 digits The 2nd digit means Coater and the 1st digit means Nozzle Total 16 ID setting is po...
Page 24: ...TP 40BA Rev 1 0 21 TALON TECH CO LTD After inputting ID touch Set ID input the password and enter After exchanging for new ID the pump is automatically initialized...
Page 25: ...el 2 Touch Config button on Select Function menu 4 Touch Pump Reset 5 Touch OK button Are you Sure window Right after touching OK Reset progresses and Alarm is clear On left Text window 0 means Initia...
Page 26: ...TP 40BA Rev 1 0 23 TALON TECH CO LTD 6 3 Touch Pad Menu Tree...
Page 27: ...es and setting changes At this time Busy window is shown normally 6 4 3 Pump ID Setting The basic ID is 11 If pump touch pad is set in the first time connect pump touch pad as 1 1 not to double ID ex...
Page 28: ...ghly 1 Take away bubbles made by PR before dispense When PR fills up in the buffer tank bubbles go up and PR goes down So PR can be dispensed without bubbles through the buffer tank bubble trap 2 Even...
Page 29: ...he degas sol work The air supplies to the degas pump and the retracted bellows pulls up PR from the PR bottle At this time the degas pump locates at the upper position 3 Degas Sol V V Operation Stop a...
Page 30: ...e driving motor driver bellows position sensors etc 2 Dispense Pump Exterior 7 2 2 Dispense Pump Operation Sequence 1 Dispensing When the controller receives the start signal or any start on communica...
Page 31: ...suck back valve is open upto the set time in order to reload At this time PR is suck backed at the tip of nozzle 3 Reload After Suck Back finish during suck back V V close the reload proceeds up to h...
Page 32: ...p is sold out the sensitivity of the buffer tank empty sensor is set But if in need to charge the buffer tank manually pls follow up the below 1 As per PIC 2 set the max to turn CCW with the driver 2...
Page 33: ...lts tightening condition and ball screw worn out condition 4 Check any interruption between cables moving parts 5 Check the conditions of linear bushing shaft when the pump works 6 Grease up on ball s...
Page 34: ...Photo Sensor 3 TL 40BA CA 001 Suck Back Valve 1 TL 40BA EB 002 Solenoid Valve DC24V 2 TL 40BA CA 003 Sol Block Ass y 1 TL 40BA EA 002 SMPS 1 Degas Pump TL 40BA TA 008 Buffer Tank 1 TL 40BA TA 009 Bel...
Page 35: ...TP 40BA Rev 1 0 32 TALON TECH CO LTD 9 2 Pump Dimensions 9 2 1 Front View 9 2 2 Side View...
Page 36: ...TP 40BA Rev 1 0 33 TALON TECH CO LTD 9 3 Touch Pad Dimensions 9 3 1 Front View 9 3 2 Rear View 9 3 3 Side View...
Page 37: ...TP 40BA Rev 1 0 34 TALON TECH CO LTD 9 4 Touch Pad Connection Board Dimensions 9 4 1 Top View...
Page 38: ...r to the picture of 3 1 Pump In Exterior Names in page 5 Insert union nuts on tube at PR In Out Vent areas 2 At PR In Out areas insert Ferrule Back Ferrule and tighten Union Nut 3 At the vent area ins...
Page 39: ...until the screw is seen And loose the screw to take the back cover apart 2 Prepare the panel to make the square hole by matching PIC 3 3 As per PIC 2 install the touch pad on the equipment 4 The panel...
Page 40: ...cket Installation Method 1 Refer to PIC 1 PIC 2 Install the bracket on the panel on the equipment 2 In case the bracket is installed PIC 1 or PIC 2 can be used THE END PIC 1 INSTALLATION SUGGESTION 1...