1-103
Bar code H:
HIBC
This is a bar code of the Code 3 of 9 HIBC (modulus 43 checksum)
version and consists of upper-case alphanumeric characters.
Number of digits is variable in length. Checksum is added to the end
of data. To specify the type of data format, enter "+" in the top of data.
Start/stop codes "
*
" are automatically added by the printer. Valid
ASCII codes are as follows: 32, 36-37, 43, 45-47, 48-57, 65-90.
The standard HIBC ratio (ratio of thick bar to thin bar) is 3 : 1, as same
as Code 3 of 9.
Bar code I: CODABAR
Basically, this code consists of only numeric characters and number of
digits is variable in length. Valid codes are "01234567-.
/ :" Standard ratio is 3 : 1. This bar code needs start/stop codes so
either of A, B, C, or D must be added to the transmission code.
Bar code J:
Interleaved 2 of 5 W/BARS
This is a bar code of the Interleaved 2 of 5 modulus 10 checksum and
even digits including checksum are variable in length. Basically,
code must be transmitted in an odd digit. The printer automatically
calculates the data and adds the checksum to the end of transmission
code. When even digit code is transmitted, the printer automatically
adds 0 (zero) to the top of data. Valid ASCII code is 48-57.
Standard ratio is 5 : 2.