EMI/EMC Statement and Manufacturer’s Declaration

This equipment has been tested and found to comply with the limits of EN 60601-1-2.
These limits are designed to provide reasonable protection against harmful interference in both a 

medical and residential environment. This equipment generates, uses and can radiate radio frequency 

energy and, if not used in accordance with manufacturer’s instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception or other 

equipment, which can be determined by turning the equipment off and on, the user is encouraged to try 

to correct the interference by one of the following measures:

l

  Reorient or relocate the receiving antenna.

l

  Increase the separation between the equipment.

l

  Connect the equipment to an outlet on a circuit different from that to which the receiver or equipment 

was connected.

The equipment having been tested to operate within the limits of electromagnetic compatibility. 

(Immunity to interference from nearby sources radiating radio frequency energy). Sources exceeding 

these limits may give rise to operation faults. Where possible the system will sense the interference and 

if it is of short duration transparently take countermeasures whilst operating near normally, or failing 

this will issue a warning and take measures for the continued safely of the user. Further increased levels 

of energy may cause the system to stop operating, continuously generate random faults or continuous 

resets.
Try to ascertain the source of the interference by turning nearby or suspect equipment off, and see if the 

interference effects stop. In any such event the user is encouraged to try to correct the interference by 

one of the following measures:

l

  Have the interfering equipment repaired or replaced.

l

  Reorient or relocate the interfering equipment.

l

  Increase the separation between the equipment and the possible source of the interference.

l

  Connect the equipment to an outlet on a circuit different from that to which the interfering equipment 

was connected.

Information regarding Electro Magnetic Compatibility (EMC) according to IEC60601-1-2

With the increased number of electronic devices such as PC’s and mobile telephones, medical devices 

in use may be susceptible to electromagnetic interference from other devices. The EMC (Electro 

Magnetic Compatibility) standard IEC60601-1-2 defines the levels of immunity to these electromagnetic 

interferences. From the other hand, medical devices must not interfere with other devices. IEC60601-1-

2 also defines the maximum levels of emissions for these medical devices. The QUATTRO

®

 conforms to 

this IEC60601-1-2 standard for immunity and emission. Nevertheless, special precautions need to be 

observed:

The QUATTRO

®

 needs to be installed and put into service according to the EMC information below.

The QUATTRO

®

 is intended for use in the electromagnetic environment specified in the tables below. 

The user of the QUATTRO

®

 should assure that it is used in such environment.

In general, although the QUATTRO

®

 complies too the EMC standards, it can be affected by portable 

and mobile RF communications equipment (such as mobile telephones).

The QUATTRO

®

 should not be used adjacent to or stacked with other equipment. In case adjacent or 

stacked use is necessary, the QUATTRO

®

 should be observed to verify normal operation.

18

Guidance and Manufacturer’s Declaration: Electromagnetic Emissions (IEC 60601-1-2)

Emissions Test

Compliance

Electromagnetic environment - guidance

RF emissions CISPR 11

Class B

The QUATTRO

®

 systems are suitable for use in all establishments, 

including domestic establishments and those directly connected to 

the public low-voltage pump supply network that supplies buildings 

used for domestic purposes.

Harmonics emissions 61000-3-2

Class A

Voltage fluctuations / flicker emissions 61000-3-3

Complies

Summary of Contents for B.A.S.E RECLINER MAT

Page 1: ...Pressure Area Care Mattresses and Cushions QUATTRO ACUTE Systems QUATTRO PLUS Systems QUATTRO OVERLAY Systems PULSAIR CHOICE Systems POLYFLOAT SUPREMA POLYFLOAT DORMIRA B A S E Seating Systems reduci...

Page 2: ...the user to the possibility of a problem with the system associated with its use or misuse Operating Instructions IP Ingress Protection 2 Protection against fingers or other object not greater than 80...

Page 3: ...n a cot size version for paediatric use l QUATTRO PLUS mattress replacement system for patients at high risk of pressure ulcers l QUATTRO OVERLAY mattress overlay system for patients at high risk of p...

Page 4: ...sing or lowering of bed or bed rails or any other moving object l The power unit must only be used with a suitable approved cord and plug set as supplied by Talley l The system is not used in the pres...

Page 5: ...injury l In order for alternating air pressure mattress cushion range to operate effectively please avoid placing objects on the surface that may obstruct the movement of air between the cells For th...

Page 6: ...d mattress and causing possible injury to the patient A strap extension kit is available for use with divan beds part number 97 50 10 153 4 Suspend the power unit from the foot board of the bed having...

Page 7: ...screen Press and hold the MUTE UNLOCK button until power unit beeps if further button operation is needed i e change of therapy mode or comfort setting 12 Place the carry bag and user manual in a safe...

Page 8: ...The mattress and cushion will operate simultaneously allowing the simple transfer of the patient between the bed and chair NB When the patient is in bed return the comfort setting to the mattress set...

Page 9: ...The power unit will lock again 2 minutes after the last button operation NB After power failure switching the power off pressing MUTE cancels the system s previous settings When power returns the def...

Page 10: ...ain inflated so supporting the patient All alternating air pressure mattresses can be used on profiling bed frames slatted frames in filled frames and divans Back rests or pillows for support should b...

Page 11: ...insed with clean water to remove any residues This will help prevent any possible long term compatibility issues associated with disinfectant residues l Alternatively disinfection may be achieved by l...

Page 12: ...iversally used on all hard and soft surfaces without any detrimental effect TECcare CONTROL is CE marked for cleaning medical equipment SERVICING Once the initial guarantee period expires Talley recom...

Page 13: ...en All systems have a fault log that records the last 5 faults via the DATA display mode If problems reoccur contact Talley AC FAIL fault indicates a mains power failure a sounder will be heard if pow...

Page 14: ...by pressing MUTE button EMI FAULT Caused by external RF fields Fault will clear when interference ceases Check air cells and tubing are intact FAULT Reset power unit by pressing MUTE button MATTRESS...

Page 15: ...gap of 2 5cm either side of the mattress should not be exceeded when side rails are deployed CUSHIONS Place the POLYFLOAT cushion onto a chair ensuring cushion is placed the correct way up N B It shou...

Page 16: ...s will help prevent any possible long term compatibility issues associated with disinfectant residues l Alternatively disinfection may be achieved by laundering at temperatures not exceeding 650 C for...

Page 17: ...Time QUATTRO ACUTE variable continuous QUATTRO PLUS 16 minutes continuous QUATTRO OVERLAY 16 minutes continuous PULSAIR CHOICE 16 minutes mattress replacement 8 minutes mattress overlay cushion conti...

Page 18: ...30mm x 430mm x 70mm UK standard size B A S E RECLINER MAT cushion 1080mm x 430mm x 70mm PULSAIR CHOICE cushion 430mm x 430mm x 40mm Weight B A S E SEQUENTIAL cushion 1 9kg n B A S E RECLINER MAT cushi...

Page 19: ...ering equipment repaired or replaced l Reorient or relocate the interfering equipment l Increase the separation between the equipment and the possible source of the interference l Connect the equipmen...

Page 20: ...separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interfer...

Reviews: