Talley B.A.S.E RECLINER MAT User Manualline Download Page 18

17

 QUATTRO

®

 PLUS/PULSAIR

®

 CHOICE MATTRESS REPLACEMENT:

 

1950mm x 880mm x 180mm

 

QUATTRO

®

 OVERLAY/ PULSAIR

®

 CHOICE MATTRESS OVERLAY: 

1930mm x 850mm x 130mm

Weight: QUATTRO

®

 ACUTE: 12.5kg (PAEDIATRIC version: 6.6kg)  

n

  QUATTRO

®

 

PLUS: 10.5kg  

n

  QUATTRO

®

 OVERLAY: 6.8 kg  

n

  PULSAIR

®

 CHOICE: 

8.6kg (mattress replacement) / 5.5kg (mattress overlay)

ALTERNATING AIR PRESSURE CUSHIONS      (

Medical Device Classification: Class 

II

a)

Construction: 

BASE: 

B.A.S.E.

®

 SEQUENTIAL / RECLINER MAT cushion:

 

Woven nylon 940 DTEX PU coated both sides

 

n

  PULSAIR

®

 CHOICE cushion: PVC coated 2oz nylon, 350 micron

 

INNER:

 B.A.S.E.

®

 SEQUENTIAL / RECLINER MAT cushion: PVC bellows 

within punched CMFR foam  

n

  PULSAIR

®

 CHOICE cushion: PU film

 

COVER: 

PU coated stretch nylon 255g/m

2

Type: B.A.S.E.

®

 SEQUENTIAL / RECLINER MAT cushion: 8/20 rows of 6 

bellow  cell strips operating in a 1-in-4 alternating air pressure cycle

 PULSAIR

®

 CHOICE cushion: One piece air cell set operating in a 1-in-2 

alternating air pressure cycle

Dimensions B.A.S.E.

®

 SEQUENTIAL cushion: 430mm x 430mm x 70mm

(UK standard size) 

B.A.S.E.

®

 RECLINER MAT™ cushion: 1080mm x 430mm x 70mm

 PULSAIR

®

 CHOICE cushion: 430mm x 430mm x 40mm

Weight: B.A.S.E.

®

 SEQUENTIAL cushion: 1.9kg;  

n

  B.A.S.E.

®

 RECLINER MAT 

cushion: 3.9kg  

n

  PULSAIR

®

 CHOICE cushion: 1.3kg

STATIC FOAM MATTRESSES & CUSHIONS      (

Medical Device Classification: Class 

I

)

Construction: 

POLYFLOAT SUPREMA™ mattress: base frame - CMHR foam 
38-40kg/m

3

/175-215 (blue); insert - Visco-elastic foam

 

57-62kg/m

3

/42-58

 

(yellow)

 

with channel-cut head and foot areas

 

POLYFLOAT DORMIRA™ mattress: base frame - CMHR foam 38-40kg/
m

3

/175-215 (blue); insert - CMHR foam 38-40kg/m

3

/110-130 

(orange) with variable width castellated surface

 POLYFLOAT™ cushion: base layer - CMHR foam 48-52kg/m

3

/200-

260 (white); top layer -  Visco-elastic foam 57-62kg/m

3

/115-155

 

 

(pink) with cross-cut surface 

Cover: 

PU coated stretch nylon 255g/m

2

Dimensions 

POLYFLOAT SUPREMA™ mattress: 1980mm x 880mm x 150mm

 

POLYFLOAT DORMIRA™ mattress: 1980mm x 880mm x 150mm

 

POLYFLOAT™ cushion:  430mm x 430mm x 76mm

Weight: 

POLYFLOAT SUPREMA™ mattress: 14.0kg

 

POLYFLOAT DORMIRA™ mattress: 11.0kg

 POLYFLOAT™ cushion:  1.0kg
Turning cycle: 

POLYFLOAT SUPREMA™ mattress: 2 way

 

POLYFLOAT DORMIRA™ mattress: 2 way

 

POLYFLOAT™ cushion: 2 way

Summary of Contents for B.A.S.E RECLINER MAT

Page 1: ...Pressure Area Care Mattresses and Cushions QUATTRO ACUTE Systems QUATTRO PLUS Systems QUATTRO OVERLAY Systems PULSAIR CHOICE Systems POLYFLOAT SUPREMA POLYFLOAT DORMIRA B A S E Seating Systems reduci...

Page 2: ...the user to the possibility of a problem with the system associated with its use or misuse Operating Instructions IP Ingress Protection 2 Protection against fingers or other object not greater than 80...

Page 3: ...n a cot size version for paediatric use l QUATTRO PLUS mattress replacement system for patients at high risk of pressure ulcers l QUATTRO OVERLAY mattress overlay system for patients at high risk of p...

Page 4: ...sing or lowering of bed or bed rails or any other moving object l The power unit must only be used with a suitable approved cord and plug set as supplied by Talley l The system is not used in the pres...

Page 5: ...injury l In order for alternating air pressure mattress cushion range to operate effectively please avoid placing objects on the surface that may obstruct the movement of air between the cells For th...

Page 6: ...d mattress and causing possible injury to the patient A strap extension kit is available for use with divan beds part number 97 50 10 153 4 Suspend the power unit from the foot board of the bed having...

Page 7: ...screen Press and hold the MUTE UNLOCK button until power unit beeps if further button operation is needed i e change of therapy mode or comfort setting 12 Place the carry bag and user manual in a safe...

Page 8: ...The mattress and cushion will operate simultaneously allowing the simple transfer of the patient between the bed and chair NB When the patient is in bed return the comfort setting to the mattress set...

Page 9: ...The power unit will lock again 2 minutes after the last button operation NB After power failure switching the power off pressing MUTE cancels the system s previous settings When power returns the def...

Page 10: ...ain inflated so supporting the patient All alternating air pressure mattresses can be used on profiling bed frames slatted frames in filled frames and divans Back rests or pillows for support should b...

Page 11: ...insed with clean water to remove any residues This will help prevent any possible long term compatibility issues associated with disinfectant residues l Alternatively disinfection may be achieved by l...

Page 12: ...iversally used on all hard and soft surfaces without any detrimental effect TECcare CONTROL is CE marked for cleaning medical equipment SERVICING Once the initial guarantee period expires Talley recom...

Page 13: ...en All systems have a fault log that records the last 5 faults via the DATA display mode If problems reoccur contact Talley AC FAIL fault indicates a mains power failure a sounder will be heard if pow...

Page 14: ...by pressing MUTE button EMI FAULT Caused by external RF fields Fault will clear when interference ceases Check air cells and tubing are intact FAULT Reset power unit by pressing MUTE button MATTRESS...

Page 15: ...gap of 2 5cm either side of the mattress should not be exceeded when side rails are deployed CUSHIONS Place the POLYFLOAT cushion onto a chair ensuring cushion is placed the correct way up N B It shou...

Page 16: ...s will help prevent any possible long term compatibility issues associated with disinfectant residues l Alternatively disinfection may be achieved by laundering at temperatures not exceeding 650 C for...

Page 17: ...Time QUATTRO ACUTE variable continuous QUATTRO PLUS 16 minutes continuous QUATTRO OVERLAY 16 minutes continuous PULSAIR CHOICE 16 minutes mattress replacement 8 minutes mattress overlay cushion conti...

Page 18: ...30mm x 430mm x 70mm UK standard size B A S E RECLINER MAT cushion 1080mm x 430mm x 70mm PULSAIR CHOICE cushion 430mm x 430mm x 40mm Weight B A S E SEQUENTIAL cushion 1 9kg n B A S E RECLINER MAT cushi...

Page 19: ...ering equipment repaired or replaced l Reorient or relocate the interfering equipment l Increase the separation between the equipment and the possible source of the interference l Connect the equipmen...

Page 20: ...separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interfer...