ENGLISH
18
3. TECHNICAL DATA - STANDARDS
Maximum working pressure:
0.6 MPA (6 bar)
Maximum working pressure for TALLAS N150/N200/N250/N300:
7,5 bar
(750 kPa)
Environment temperature:
+40°C
Liquid temperature range:
from 0°C to +35°C according to EN 60335-2-41 for
domestic use.
Liquid temperature range for TALLAS N 100 T :
from 0°C to +40°C
Flow rate:
from 0,6 to 5,5 m³/h
Flow rate for TALLAS N150/N200/N250/N300:
from 0,6 to 10,5 m³/h
Head:
up to 58 m.
Head for TALLAS N150/N200/N250/N300:
up to 60 m.
NOISE LEVEL:
directive 2000/14/CE
NOISE LEVEL for TALLAS N150/N200/N250/N300:
directive EC 89/392/CEE
MOTOR CONSTRUCTIONS :
standards IEC 2-3 IEC 61-69 (EN 60335-2-41)
4. INSTALLATION
The electropump must be positioned as close as possible to the liquid to be
pumped.
Install a foot valve on suction.
Tallas N 100 T
:
For three-phase motors check the correct direction of rotation of
the motor which must be clockwise. Otherwise invert any two phase leads, after having
disconnected the electropump from the power mains.
Pipes not weighing down on the electropump.
Suction pipe diameter > = diameter of the electropump opening.
Installation in a horizontal position.
Positive slope of the suction pipe towards the electropump.
Summary of Contents for GC50 + KIT 4M
Page 67: ......
Page 68: ...03 14 cod 0013 613 01 ...