ENGLISH
2
These pumps cannot be used in swimming pools, ponds or basins where people are present, or for
pumping hydrocarbons (petrol, diesel fuel, combustible oils, solvents, etc.) in accordance with the acci-
dent-prevention regulations in force. They should be cleaned before putting them away. See the chapter
“Maintenance and Cleaning”.
2. PUMPABLE LIQUIDS
Clean, free from solid bodies or abrasive substances, non-aggressive.
Fresh water
Fountain water (filtered)
Rainwater
(filtered)
River or lake water (filtered)
Clear waste water
o
Drinking
water
Dirty water
o
Suitable
o
Not
suitable
3. TECHNICAL DATA AND LIMITATIONS OF USE
Supply voltage:127V,
see electrical data plate
Delayed line fuses (127V 60Hz version):
indicative values (Ampere)
Storage temperature:
-10°C – 40°C
Model P1=1124
W
Electrical
data
P1 Rated absorbed power [W]
1124
P2 [W]
800
USA P2 [HP] Fractional (decimal)
1.1
Mains voltage [V]
~ 127V AC
Mains frequency [Hz]
60
Current [A]
8.9
Capacitor [µF]
40
Capacitor [Vc]
250
Hydraulic
data
Max. flow rate [l/min]
57
Max. head [m]
45
Max. pressure [bar]
6
Max suction depth [m]
8/<3min
Range of
use
Type of cable
SJTOW 16AWG
Grade of motor protection
IP X4 / NEMA 3
Insulation class
F
Liquid temperature range [°C]
according to EN 60335-2-41 for domestic use
+0°C / +35°C
Max. particle dimension
Clean water
Max. ambient temperature [°C]
40°C
Weight
DNM NPT
1'' M
Table 2a
Supply voltage:230,
see electrical data plate
Delayed line fuses (230V 60Hz version):
indicative values (Ampere)
Storage temperature:
14 F – 104 F
Model P1=1060
W
Electrical
data
P1 Rated absorbed power [W]
1060
P2 [W]
750
USA P2 [HP] Fractional (decimal)
1.01
Mains voltage [V]
~ 230V AC
Mains frequency [Hz]
60
Current [A]
4.8
Capacitor [µF]
16
Capacitor [Vc]
450
Hydraulic
data
Max. flow rate [gpm]
15.3
Max. head [ft]
146.7
Max. pressure [psi]
87
Max suction depth [ft]
26.2/<3min
Range of
use
Type of cable
SJTOW 16AWG
Grade of motor protection
IP X4 / NEMA 3
Insulation class
F
Liquid temperature range [F]
according to EN 60335-2-41 for domestic use
+32 F / +95 F
Max. particle dimension
Clean water
Max. ambient temperature [F]
104
Weight
DNM NPT
1'' M
Table 2b