background image

OY1700 LoRaWAN Air quality (PM) sensor, User manual, Version 0.1 
 

5

 

Installation and activation 

The sensor consists of a bottom piece, the electronic board and the top cover. Remove the top 

cover by pressing it upwards and outwards. The electronics are removed by releasing the 

plastic latch on the top.  

 

 

The bottom piece is mounted on the wall with the “UP” arrow upwards. It can be mounted 

either with screws or adhesive tape both included in the package. The hole pattern matches 

standard junction box. 

Summary of Contents for OY1700

Page 1: ...OY1700 LoRaWAN Air quality PM sensor User manual Version 0 1 September 2019...

Page 2: ...nfiguration 8 5 2 Sensor states and state check 8 5 2 1 Re join functionality 10 6 Specification 11 7 Security 13 8 Protocol 13 8 1 LoRaWAN standard commands 13 8 2 Unsolicited uplink status commands...

Page 3: ...rtify that the design and manufacturing of this product WIRELESS CO2 SENSOR FUNK CO2 SENSOR TR DL S CO2 SENSOR TR D S CO2 SENSOR DRAADLOZE CO2 SENSOR OY1210 EU868 conforms to the following directives...

Page 4: ...collection point designated for the recycling of electrical and electronic appliances Separate collection and recycling of your waste at the time of disposal will contribute to conserving natural res...

Page 5: ...to measure PM10 PM2 5 PM1 0 temperature and humidity in indoor environments The sensor is intended for indoor climate control and monitoring indoor air quality It is optimized for reliable and secure...

Page 6: ...board and the top cover Remove the top cover by pressing it upwards and outwards The electronics are removed by releasing the plastic latch on the top The bottom piece is mounted on the wall with the...

Page 7: ...C The cable can be routed through the cable canal or through the electronic board for junction box mount The sensor starts and flashes 8 times during the boot up sequence and starts the join sequence...

Page 8: ...onfigured with device unique DevEUI and AppKey The DevEUI is printed on device box and the AppKey is distributed by the sales team The device is default configured for OTA provisioning Contact the Tal...

Page 9: ...in is indicated with a 2 sec long flash To check the device state press the button and hold it pressed until the red LED starts flashing after 0 5s State Description LED response Initial Low power sta...

Page 10: ...es temperature and humidity periodically and sends measurement reports toward a LoRAWAN network 1 long flash 2 sec 5 2 1 Re join functionality The device supervises its connectivity to the network by...

Page 11: ...nditions 10 90 RH Humidity range 0 to 100 non condensing Particulate matters ranges PM1 0 PM2 5 PM10 Connectivity Network LoRaWAN Frequency bands 868 MHz Provisioning Over the air personalization Size...

Page 12: ...rsion 0 1 12 Configuration Measurement intervals 15 minutes configurable over the air Transmission intervals 15 minutes configurable over the air Unique App EUI available upon request Enclosure IP30 C...

Page 13: ...Uplink query response Note 0x denotation means hexadecimal encoded 8 1 LoRaWAN standard commands All standard LoRaWAN v 1 0 2 are supported Please refer to the LoRaWAN standard for the protocol defin...

Page 14: ...load Measurement value see chap 8 3 2 Size 5 Bytes 8 3 2 Measurement value The measurement value for each measurement Byte 0 Temperature bit 11 bit 4 Byte 1 Relative humidity bit 11 bit4 Byte 2 bit 7...

Page 15: ...ided with 10 to get it in RH 8 3 2 3 Particulate Matter PM conversion The Particulate Matter of different sizes PM10 PM2 5 and PM1 0 are measurement in parts per million ppm 1 x 10 6 is transmitted us...

Page 16: ...e sent from the server application Contact your LoRaWAN network provider for in band application API All downlink application communication is done on LoRaWAN port 1 Downlink command network device Fi...

Page 17: ...CPU temperature Uint16 Big endian 50C 0 01C LSB 50 125 C Query No Temperature from CPU sensor with 50 C offset Approximately 5 C accuracy 1 0x20 Status Uint8 Bitfield Query Yes Should be 0 otherwise...

Page 18: ...t 1 01230005 Set measurement interval to 15 minutes Port 1 0123000F 8 4 2 Reset device The device can be remotely reset and forced into Joining state All settings are back to factory default Example R...