background image

WEBS-PM 

 Pedestal Mount 

Emergency Phone Station with WEBS

®

 

Installation Instructions

 

Copyright 2014 Talk-A-Phone Co.

 

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.

 

All prices and specifications are subject to change without notice. Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talk-A-Phone Co. All rights reserved.

 

Page 2 of 4

 

 
 
 

 

 
 

 
 
4. 

Install one 3/4” nut and one washer on each anchor bolt 2.5”

-3.5" above grade to top of washer.  This 

will allow for a 

1/2" air gap

 between the foundation and the Pedestal which will allow airflow and 

prevent moisture problems.  Verify that the nuts are level (0° pitch). 

 

NOTE:  

To insure proper grounding of all electrical components, the tower mount should be effectively earth 

grounded from the grounding stud (located across from the lower access panel) with 6 AWG or better insulated, 
stranded copper wire to the metallic power service raceway (conduit) or an 8' or longer corrosion-resistant ground 
spike. 

 

 
5.  After removing the lower access panel of the Pedestal, install the tower onto the bolts with the 

Emergency Phone opening oriented in the desired direction.  Install second set of nuts and washers.  
Tighten the upper nuts; the bottom set is used only for leveling. 

 

 
 
 
 
 
 
 

Summary of Contents for WEBS-PM

Page 1: ...on 4 42838 J Bolts 8 42839 3 4 10 Hex Nut 8 42840 3 4 Washer 3 42867 10 24 x 1 2 Tamper Resistant Screws 2 42843 6 32 Hex Nut 1 68590 LED Panel Light 12 24VAC DC 120VAC 1 67478 Polycarbonate Cover for LED Panel Light 1 24717 Pedestal Mount Aluminum Template III Installation 1 Electrical and telephone line conduits should be run through the foundation and into the center 4 diameter hole of the Pede...

Page 2: ... air gap between the foundation and the Pedestal which will allow airflow and prevent moisture problems Verify that the nuts are level 0 pitch NOTE To insure proper grounding of all electrical components the tower mount should be effectively earth grounded from the grounding stud located across from the lower access panel with 6 AWG or better insulated stranded copper wire to the metallic power se...

Page 3: ...egarding device configuration and programming 5 For the WEBS PM 120VAC 240VAC power option connect the input power supply of the WEBS AMP 2 amplifier to 120VAC 240VAC 60Hz brown is positive blue is neutral 6 For the WEBS PM 12 24 VDC power option connect the WEBS AMP 2 amplifier to 12VDC 3A input white is positive black is negative 7 Mount the two 2 loudspeakers behind the appropriate speaker gril...

Page 4: ...ue Niles Illinois 60714 Phone 773 539 1100 info talkaphone com www talkaphone com All prices and specifications are subject to change without notice Talk A Phone Scream Alert WEBS and WEBS Contact are registered trademarks of Talk A Phone Co All rights reserved Page 4 of 4 All dimensions are in inches and are provided for reference only ...

Reviews: