WEBS-MT/R Tower Installation Instructions
Copyright 2011 Talk-A-Phone Co. All rights reserved.
Page 7 of 8
Talk-A-Phone Co.
• 7530 North Natchez Avenue • Niles, Illinois 60714-3804
Phone 773.539.1100 • Fax 773.539.1241 • [email protected] • www.talkaphone.com
All prices and specifications are subject to change without notice.
Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co.
3. Connect the
WEBS-VCU
and the DIN Rail Terminal Block as shown in
Figure 5
.
38
Paging
Amplifier
WEBS-VCU
Microph
one Input
WEBS-
C
M
-2 /
WEBS-
ZP
S Input
Audio
Output 1
Power / Trigger
Audio
Output 3
Audio
Output 4
Audio
Output 2
[WHITE]
[GREEN]
[RED]
[BLACK]
[BLACK]
[RED]
[WHITE]
[YELLOW] –
BARE SHIELD
[GREEN]
RCA CABLE 1
RCA CABLE 2
RCA CABLE 3
RCA CABLE 4
}
39
40
41
42
43
44
45
46
{
{
To DIN Rail
Terminal Block
To DIN Rail
Terminal Block
[RED / BROWN]
[BLACK / GREEN]
[BLACK]
[ORANGE]
7
8
52
54
Figure 5.
WEBS-VCU, Paging Amplifier and DIN Rail Terminal Block Connectivity Layout
4. When using
WEBS-CM-2
or
VOIP-500 Series
Emergency Phone make connections to the DIN Rail
Terminal Block as shown in
Figure 6
.
VOIP-500 /
WEBS-CM-2
Audio Output
Auxiliary Output
[Dry Contact Closure]
[GREEN]
[WHIT
E]
[RED]
Audio Li
ne Level
Twisted Shield
ed
Pair Cabl
e
Twisted One Pair Shielded
And One Pair Unshielded Cable
[BLACK]
[RED]
[BLACK]
[WHITE]
[GREEN]
13
14
15
16
}
To DIN Rail Terminal
Block
Figure 6.
VOIP-500 / WEBS-CM-2 and DIN Rail Terminal Block Connectivity Layout