Talkaphone AOR-8 Installation Manual Download Page 7

 

Area of Rescue Command Unit

 

Installation Guide 

Model AOR-8 / Model AOR-16

 

Page 

7

 of 

10

 

 

  Rev. 6/28/2017

 

 

Copyright 2017 Talk-A-Phone Co.

 

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com. 

 

 

All prices and specifications are subject to change without notice. Talk-A-Phone, Talkaphone, Scream Alert, WEBS, and WEBS Contact are registered trademarks of Talk-A-
Phone Co.  All rights reserved.  All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any 
approval, endorsement, sponsorship, or affiliation with such owners unless such approval, endorsement, sponsorship, or affiliation is expressly indicated. 

Programming the Analog Call Stations 

Once each Consolidator has been programmed, each Talkaphone Analog Call Station must be 
programmed individually.  A call can be routed to the desired phone port by entering the following 
code: 

*4X* 

Routes to Analog Call Station in port number X (X=1-8) 

For details on programming the Talkaphone Analog Call Stations, refer to the Installation & 
Operation Manual for Emergency/Information Phones.  (Note: if the Consolidator is in Remote Mode 
or Day/Night Mode and your remote phone line is a PBX extension, be sure to program the 
emergency phones for Mode 2.  See Emergency Phone Manual, pages 11 and 15 for more 
information on Modes). 

 

Code Summary 

Command 

Function 

*31* …[up to 8 digits]*

 

Guard 

Access 

Code 

entry 

for 

phone 

programming 

(Default Code is *31**)

 

*30* …[up 

to 8 digits]* 

Master  Access  Code  entry  to  change  Guard  Access  Code  or 
Master Access Code  

(Default Code is *30*12345678*) 

*30*14725836* 

Resets Consolidator programming to factory defaults 

*32* …[up to 8 digits]*

 

Programs and stores a new Master Access Code 

*33* …[up to 8 digits]*

 

Programs and stores a new Guard Access Code 

*34* …[up to 2 digits]*

 

Sets number of rings before consolidator picks up when it is dialed 

*62* 

Remote Mode (default) 

*37* 

Local Mode 

*63* 

Day/Night Mode 

*35* 

In Day/Night Mode, call LOCAL PHONE then TELCO IN 

*36* 

In Day/Night Mode, call TELCO IN then LOCAL PHONE 

*39*...[1 or 2]* 

Program the type of phone line in the TELCO IN 
*39*1*  for ordinary phone lines (default) 
*39*2*  for PBX lines 

*4...[1-8]* 

Routes to Analog Call Stations in Port #1-8 

 

Summary of Contents for AOR-8

Page 1: ...es Analog Call Stations It is recommended that this instruction set be read completely prior to the start of any installation II Contents Please ensure receipt of each of the included AOR 8 AOR 16 com...

Page 2: ...distributor immediately Do not discard any hardware or packaging prior to checking for all included components listed above and the unit is installed and functioning correctly 2 Remove the three 3 Phi...

Page 3: ...rnal compartment The Black wire is a common negative and needs to be connected to both the strobe and siren negative terminals The Red White wire gets connected to the Positive terminal of the strobe...

Page 4: ...e In Remote Mode pressing the button on any of the Talkaphone Analog Call Stations will cause them to access a phone line to dial out For this configuration connect an outside phone s line to the Telc...

Page 5: ...enough rings for the person answering the phone to pick up WARNING The other device sharing the line should never be emergency equipment of any kind including another bank of the AOR 16 19 Once the c...

Page 6: ...uccessfully 2 Beeps Error s detected If you hear two beeps enter the code again If you hear two beeps a second time hang up and try again Remote Mode In Remote Mode if a standard telephone company pho...

Page 7: ...details on programming the Talkaphone Analog Call Stations refer to the Installation Operation Manual for Emergency Information Phones Note if the Consolidator is in Remote Mode or Day Night Mode and...

Page 8: ...seize the line on behalf of the Analog Call Station When a call comes in to the AOR 8 AOR 16 unit an LED will light indicating which Analog Call Station is calling in If a call is already being answe...

Page 9: ...0 feet 18 AWG 1 801 3 000 feet 16 AWG 3001 5 000 feet 14 AWG Distance from AOR 8 AOR 16 Unit to Local Phone Recommended Wire Gauges 0 1000 feet 24 AWG 1001 1500 feet 22 AWG 1501 2000 feet 20 AWG 2001...

Page 10: ...epartment 4 There isn t enough power on the line see Technical Requirements page 3 5 You may have accidentally plugged a PBX line or phone company line into the Local port If so contact Talkaphone tec...