Talk-a-Phone ETP-120 Series Installation & Operation Manual Download Page 12

 

 

ETP-120

 

Series Phone 

Installation & Operation Manual

 

 

Page 

12

 of 

27

 

 

 

Rev. 7/2/2021

 

 

Copyright 2021 Talk-A-Phone, LLC

 

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.  

 

All prices and specifications are subject to change without notice. Talk-A-Phone, Talkaphone, bAlert, Scream Alert, WEBS, and WEBS Contact are registered trademarks of Talk-A-Phone, 
LLC.  All rights reserved.  All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any approval, endorsement, 
sponsorship, or affiliation with such owners unless such approval, endorsement, sponsorship, or affiliation is expressly indicated. 

  Security Code 

When 

Mode Configuration DIP Switch #3 

is in the 

ON 

position, the ETP-120 Series Call Station will 

require a security code before it can be programmed. 

The default security code is: 

827827

 (or 

TAPTAP

)

 

Talkaphone highly recommends that this security code be changed from the default value.  To change 
the security code, follow these steps: 

1.  Access programming mode as outlined in 

Section 3.2

2.  Enter: 

☐☐☐☐☐☐

 # 19

 

 

3.  Hang up or enter this code to disconnect: 

# 7

 

If the security code is lost or forgotten, either reprogram the security code when 

Mode Configuration 

DIP Switch #3

 is set to the 

OFF

 position or reset the unit to factory defaults. 

 

 

NOTE: 

The security code must be comprised of six (6) numeric digits. 

Summary of Contents for ETP-120 Series

Page 1: ...ce Talk A Phone Talkaphone bAlert Scream Alert WEBS and WEBS Contact are registered trademarks of Talk A Phone LLC All rights reserved All other trademarks mentioned in this document or website are th...

Page 2: ...t 7 Auxiliary Output 7 4 Speaker and Microphone Volume 8 5 Mode Configuration DIP Switches 9 6 Software Programming 10 Quick Programming Guide 10 Accessing Programming Mode 11 Security Code 12 Summary...

Page 3: ...Qty 4 6 32 Stainless Steel TS 10 Pin in Torx screws P N 42937 You should inspect the analog call station when unpacking the box for possible damage in shipment If it is damaged or any of the component...

Page 4: ...personnel only in accordance with the National Electrical Code and other federal state and local statutes and building codes Using shielded cable is recommended to avoid noise hum and other operation...

Page 5: ...ioned in this document or website are the property of their respective owners and does not imply or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval e...

Page 6: ...rks of Talk A Phone LLC All rights reserved All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any approval endorseme...

Page 7: ...ners unless such approval endorsement sponsorship or affiliation is expressly indicated 3 Auxiliary Inputs Outputs All ETP 120 Series models include one 1 Auxiliary Input Some models are optionally av...

Page 8: ...or decrease the speaker volume please refer to the illustration below to determine how to adjust the speaker volume DIP Switches 1 and 2 are provided to configure a few audio detection modes as outlin...

Page 9: ...ssly indicated 5 Mode Configuration DIP Switches Mode Configuration DIP Switches 1 2 and 3 are provided to configure a number of modes as outlined below Mode Configuration DIP Switch Position Function...

Page 10: ...eaker are active 2 Enter the default security code 827827 or TAPTAP 3 Program the Primary Phone Number to dial 0 20 digits for phone number 00 For dialing a number on a POTS or PSTN telephone line i e...

Page 11: ...e 2 Call into the ETP 120 Series Call Station 3 Enter the default security code 827827 or TAPTAP 4 The call station will output a double beep and enter programming mode any programming code s may now...

Page 12: ...on with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated Security Code When Mode Configuration DIP Switch 3 is in the ON position the ETP 120 Series Call...

Page 13: ...phone number for Auxiliary Input 0 20 digits 08 Secondary autodial phone number for Auxiliary Input 0 20 digits 09 Third autodial phone number for Auxiliary Input 6 digits 17 Voice message other opti...

Page 14: ...ing pagers or voice mail systems use 7 in the dial string where a pause is required Autodial Phone Numbers for the Auxiliary Input When a dry contact closure is provided to the Auxiliary Input the uni...

Page 15: ...een talk and listen modes i e VOX switching time 1 0 1 seconds 2 0 2 seconds Default 3 0 3 seconds 4 0 4 seconds 5 0 5 seconds 6 0 6 seconds 7 0 7 seconds 8 0 8 seconds 9 0 9 seconds B Call Length Set...

Page 16: ...A B Two Digit Voice Message Delay Sets the amount of time required to elapse 1 99 seconds after dialing the phone number before the voice message plays Factory set to automatically start playing the v...

Page 17: ...dialing process stops and the ETP 120 unit hangs up When the lap counter is disabled default if the ETP 120 unit is programmed to dial the next number on ring no answer and or busy signal the ETP 120...

Page 18: ...Configuration DIP Switch 3 to the OFF position programming mode and activate the pushbutton The unit will then call Talkaphone Technical Support no matter if it is connected directly to a PSTN line o...

Page 19: ...e advised of the physical location of the phone call through either the voice message or the information displayed in the Talk A Lert software when it decodes the DTMF ID number Once the ANSWERED LED...

Page 20: ...ss such approval endorsement sponsorship or affiliation is expressly indicated Answering a Call from the ETP 120 at the Remote Side 1 The telephone at the remote side answering point or receiving end...

Page 21: ...n can Talkaphone access my unit through a software backdoor to retrieve it Answer Unfortunately not If the security code is lost or forgotten either reprogram the security code when Mode Configuration...

Page 22: ...swering point remote side will hear this voice message before the unit establishes two way communication The unit does not hang up 1 The unit is not programmed properly see Software Programming Sectio...

Page 23: ...terms and conditions Warranty period for Area of Rescue Products is sixty 60 months under the same terms and conditions Warranty period for Intercommunication Products is twelve 12 months under the sa...

Page 24: ...name and model causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required However if advance notice is not practical...

Page 25: ...ffiliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated 12 Part 15 Limitations This equipment has been tested and found to comply with the limits...

Page 26: ...cleanser and water Deeper stains may be removed with a magnesium oxide ammonia and water paste Wipe clean with water rinse and dry the faceplate Light corrosion or rusting on the faceplate can be rem...

Page 27: ...y or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated 14 ETP 120 Series Call Station Ins...