Connecting the DP sensor to the filter system
The DP sensor is connected to the filter system by 2 command tubes, the one which comes
from the filter inlet (High pressure) will be connected to the red point, and the one that
comes from the outlet (Lower pressure) will go to the black point. It is important to put a
small filter of 120 mesh (not supplied) between the red point and the high pressure
connection point.
Low Battery
The unit has two levels of low battery indication. At the first level when the battery voltage
drops to the first level, the sign will start to appear at the screen. When the battery
voltage drops further and reaches the second level, all outputs will shut down, the screen
will be cleared leaving only the low battery icon.