AC MODEL 

 
The drawing below shows the wiring of the AC model of the controller.  
 

Notice that:  

1. 

The  External  DP  sensor  is  optional  and  it  is  intended  for  use  in  cases  there  is  no 
Embedded Electronic DP included.  

2. 

The powering of the unit is by 24VAC transformed from 220/110 VAC.  

3. 

The solenoids will be of 24VAC. 

  
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Make sure  to DISCONNECT the 

POWER before inserting / removing 

the 2 ouputs plug-in unit. 

 

Summary of Contents for FILTRON 1-10 AC

Page 1: ...D NAAMAN CENTER HAIFA ACCO ROAD 7000 P O BOX 775 KIRYAT MOTZKIN 26119 ISRAEL TEL 972 4 8775947 972 4 8775948 FAX 972 4 8775949 E mail talgil33 netvision net il FILTRON 1 10 DC AC U S E R S M A N U A L...

Page 2: ...red by 110v or 220v from which it generates the 24v AC for the solenoids Flushing cycles may be triggered either by time or by the embedded electronic DP sensor reaching the set point or by a dry cont...

Page 3: ...blinking Once entering this process of passing through the editable fields the user has no way back but by pushing the ENTER key repeatedly he passes through the chain of editable fields until arrivin...

Page 4: ...Flush Mode The Flush Mode defines how the flushing cycles is triggered The selectable options are as follows OFF no flushing will take place By time In this case the flushing cycles will be repeated...

Page 5: ...e selectable delay steps are 5 10 15 20 25 30 35 40 45 50 55 sec 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 min Dwell time the delay between stations can be set to 5 10 15 20 25 30 35 40 45 50 55 or 60 sec DP de...

Page 6: ...es the flushing sequence will start from the beginning rather than continue from the stop point Connecting the DP sensor to the filter system The DP sensor is connected to the filter system by 2 comma...

Page 7: ...1 Valve 2 Pre Dwell Flush time Valve 3 Valve 4 Dwell time Main valve Valve 1 Valve 2 Pre Dwell Flush time Valve 3 Valve 4 Delay valve Dwell time V V Valve Delay Timing Diagram Without Delay Valve Inc...

Page 8: ...at 1 The External DP sensor is optional and it is intended for use in cases there is no Embedded Electronic DP included 2 The powering of the unit can be either by 6v DC or 12v DC 3 The solenoids will...

Page 9: ...External DP sensor is optional and it is intended for use in cases there is no Embedded Electronic DP included 2 The powering of the unit is by 24VAC transformed from 220 110 VAC 3 The solenoids will...

Page 10: ...Embedded electronic analog DP sensor or external dry contact DP sensor Pressure Sensor Dry contact pressure sensor Operating temperature 0 60 C AC MODEL Power source 220 or 110 v AC 50 or 60 Hz with...

Reviews: