PRODUCT SPECIFICATION

名称

:

Installation manual for crystalline

solar photovoltaic modules(Half Cell)

SPEC.NO.

TS-ET-xx

REVISION

A0

EFFECTIVE DATE

03-2020

Page

4

of

27

Suzhou Talesun Solar Technologies Co., Ltd

Address: No. 1 Talesun Road, Changkun Industrial Park, Shajiabang Town, Changshu, Suzhou, Jiangsu Province, 215542, P.R.China

Website:

www.talesun.com

Email:

[email protected]

Tel: +86 400 885 1098

4 / 28

If your questions are not adequately addressed in this manual, please first contact your system supplier. You can find
more information on our website www.talesun.com.

1.3

PRODUCTION IDENTIFICATION

Each module has three labels that provide the following information:

Nameplate: describes the product type; rated power, rated current, rated voltage, open circuit voltage, short circuit
current, all as measured under standard test conditions; weight, dimension etc.; the maximum system voltage is 1000
volts DC is shown on the nameplate. Maximum fuse rating is also shown.

“QA Pass” stamp: module will be strictly inspected according to standard and get a QA Pass stamp on the backsheet.

2-dimensional Bar code: The serial number has 16 digits. There are two bar codes on each module. One is permanently
attached to the interior of the module and is visible when viewing the front of the module, and another is stuck to the
rear side of the module.

Removing a label will make the Talesun warranty void.

2 SAFETY GUIDELINES

2.1

GENERAL SAFETY GUIDELINES

DANGER! Danger due to electric shock!

All installations must be performed in compliance with all applicable regional and local codes, or
other national or international electrical standards as applicable.

A solar module generates electricity and voltage even at low intensity of illumination.

Physically disconnecting contacts in a live electrical circuit can cause arching, resulting in

grave or mortal injury. The severity increases when several modules are connected in series.

Cover the solar modules with opaque material for the entire duration of assembly. Only then is the module reliably de-
energized.

Never disconnect plugs when under load. Be aware that even without the presence of daylight, residual charge may still
be present in the plant. Ensure that the modules are first disconnected from the inverter prior to opening any contacts
in the solar installation.

Artificially concentrated sunlight shall not be directed on the module. Solar modules produce electrical energy when
light shines on their front surface. The DC voltage may exceed 30V. Contact with a DC voltage of 30V or more is
potentially hazardous.

In the case of module or phase voltages of more than 120 V, the extra-low voltage range is left. Undertake the
necessary protective and precautionary measures.

Do not insert electrically conductive parts into the plugs and junction box. Do not touch the contacts or exposed
terminals.

Keep children and unauthorized persons away from the modules.

In case of damaged modules or operational errors of the solar array, always contact your installer or Talesun Technical
Customer Service.

Summary of Contents for TP6L60M-320

Page 1: ...ebsite www talesun com Email sales talesun com Tel 86 400 885 1098 REVISIONS Suzhou Talesun Solar Technologies Co Ltd REV ECN NPA DESCRIPTION OF CHANGE CHK D DATE APP D DATE TITLE Installation manual...

Page 2: ...of 27 Suzhou Talesun Solar Technologies Co Ltd Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email sales...

Page 3: ...28 INDEX 1 INTRODUCTION 1 1 PURPOSE OF THE MANUAL 1 2 DISCLAIMER OF LIABILITY 1 3 PRODUCTION IDENTIFICATION 2 SAFETY GUIDELINES 2 1 GENERAL SAFETY GULDELINES 2 2 PRODUCT PRECAUTION 2 3 TRANSPORT AND S...

Page 4: ...eaning This manual and the instructions set forth herein are part of the product and should therefore be kept for the entire useful life of the solar installation Information for operators Keep these...

Page 5: ...TY GUIDELINES DANGER Danger due to electric shock All installations must be performed in compliance with all applicable regional and local codes or other national or international electrical standards...

Page 6: ...for use in this application class may be used in systems operating at greater than 50V DC or 240W where general contact access is anticipated Modules qualified for safety through this part of IEC6173...

Page 7: ...nti salt function when the distance is between 100m and 1km A module is considered shade free when it is entirely unshaded throughout the year e g by buildings chimneys trees Even partial shading of t...

Page 8: ...mended standoff height is 10cm Clearance of 1 4 of an inch 6 35 mm or more between modules is required to allow for thermal expansion of the frames For roof mounting applications the assembly is to be...

Page 9: ...ture Use appropriate corrosion proof fastening materials All mounting hardware bolt split washer flat washer nut should be stainless steel M8 size And the parts in contact with the frame should use th...

Page 10: ...not mounted following the instructions above b Clamping installation Modules can be installed with clamps Modules must be securely attached to the mounting structure with four clamps on the long fram...

Page 11: ...pe Module Dimension Length Width Thickness Load A Distance from module edge to clamping zone B Clamping zone TP6L72 H series 2098mm 1046mm 35mm Negative 1600Pa 440mm 100mm Positive 3600Pa 440mm 100mm...

Page 12: ...r need to pay more attention to avoid the PID phenomenon when installing the electrical system 4 3 GENERAL INSTALLATION Before installing modules contact the appropriate authorities to determine permi...

Page 13: ...oid the PID phenomenon of the module in addition and professional person is needed to undertake the polarity negative ground operation of the inverter If the support frame is made of metal the surface...

Page 14: ...1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email sales talesun com Tel 86 400 885 1098 13 28 frame The recommende...

Page 15: ...VISION A0 EFFECTIVE DATE 03 2020 Page 14 of 27 Suzhou Talesun Solar Technologies Co Ltd Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R C...

Page 16: ...exchange is made by an authorized person Protect yourself from electric shocks while debugging or maintaining the solar power system Bypass diode type Manufacturer Schottky GF2545MG Shandong DIYI Sci...

Page 17: ...s Type 6inch 3inch 144cells Mono crystalline 6inch 3inch 120cells Mono crystalline Dimension mm 2098 1046 35 1758 1046 35 Weight kg 25 5 21 Module Maximum System Voltage V Pmax W Vmpp V Impp A Voc V I...

Page 18: ...ng A TP6L60M 375 1000 IEC 375 35 2 10 66 41 3 11 31 20 TP6L60M 370 1000 IEC 370 34 9 10 61 41 1 11 26 TP6L60M 365 1000 IEC 365 34 6 10 56 40 9 11 20 TP6L60M 360 1000 IEC 360 34 3 10 50 40 7 11 15 TP6L...

Page 19: ...oltage V Pmax W Vmpp V Impp A Voc V Isc A Fuse Rating A TP6L60M H 375 1500 IEC 375 35 2 10 66 41 3 11 31 20 TP6L60M H 370 1500 IEC 370 34 9 10 61 41 1 11 26 TP6L60M H 365 1500 IEC 365 34 6 10 56 40 9...

Page 20: ...Tokyo Japan 105 0001 Email japan talesun com Web www talesun com jp T 03 5733 3498 F 03 34341515 USA 25 METRO DRIVE Suite 228 San Jose CA 95 110 USA Email sales talesun com Tel 408 638 7627 Fax 408 64...

Page 21: ...age 20 of 27 Suzhou Talesun Solar Technologies Co Ltd Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email...

Reviews: