1.3 PRODUCTION IDENTIFICATION
Each module has three labels that provide the following information:
· Nameplate:
describes the product type; rated power, rated current, rated voltage, open circuit voltage, short
circuit current, all as measured under standard test conditions; weight, dimension etc.; the maximum system
voltage is 1000 volts DC is shown on the nameplate. Maximum fuse rating is also shown.
· “QA Pass” stamp:
module will be strictly inspected according to standard and get a QA Pass stamp on the
backsheet.
· 2-dimensional Bar code:
The serial number has 16 digits. There are two bar codes on each module. One is
permanently attached to the interior of the module and is visible when viewing the front of the module, and an-
other is stuck to the rear side of the module.
· Removing a label will make the Talesun warranty void.
2 SAFETY GUIDELINES
2.1 GENERAL SAFETY GUIDELINES
DANGER! Danger due to electric shock!
All installations must be performed in compliance
with all applicable regional and local codes, or other national or international electrical standards
as applicable.
· A solar module generates electricity and voltage even at low intensity of illumination.
· Physically disconnecting contacts in a live electrical circuit can cause arching, resulting in grave or mortal injury.
The severity increases when several modules are connected in series.
· Cover the solar modules with opaque material for the entire duration of assembly. Only then is the module reli-
ably de-energized.
· Never disconnect plugs when under load. Be aware that even without the presence of daylight, residual charge
may still be present in the plant. Ensure that the modules are first disconnected from the inverter prior to opening
any contacts in the solar installation.
· Artificially concentrated sunlight shall not be directed on the module. Solar modules produce electrical energy
when light shines on their front surface. The DC voltage may exceed 30V. Contact with a DC voltage of 30V or
more is potentially hazardous.
· In the case of module or phase voltages of more than 120 V, the extra-low voltage range is left. Undertake the
necessary protective and precautionary measures.
· Do not insert electrically conductive parts into the plugs and junction box. Do not touch the contacts or exposed
terminals.
· Keep children and unauthorized persons away from the modules.
· In case of damaged modules or operational errors of the solar array, always contact your installer or Talesun
Technical Customer Service.
· Do not wear metallic ornaments or metallic devices while installing or troubleshooting photovoltaic systems.
Installation manual for crystalline solar photovoltaic modules