background image

1.   Make sure the 3-way rocker switch is in the center, standby position. Plug the 

power cord into a properly grounded outlet. The unit is now on and in a standby 

mode.

2.  For continuous operation, push the rocker switch to the right, on position. For 

intermittent/touch operation, push the rocker switch to the left, auto position.

3.   In either case, set the speed. In the on position, you will see the head in motion 

immediately. In the auto position, the vessel you are using must be pushed down 

on the head attachment to achieve motion. To get the desired mix, vary the speed, 

using the speed up/down arrows, and/or vary the angle of contact and pressure 

against the head.

  Setting speed:

   To set the speed press the up/down arrows below the speed display until you reach 

the desired speed.

    •   Speed while running in the on position is 500 to 3000rpm (500 to 2500rpm 

 for  230V).

    •   Speed  while  running  in  the  auto  position  is  1000  to  3000rpm  (1000  to 

2500rpm for 230V).

    •   Speed while running in the pulse mode is 3000rpm, running for 30 seconds, 

resting 10 seconds (2500rpm for 230V).

  Setting time:

  Time operation works in both auto and on positions.

    •   To run in timed mode (programmed time), start by pressing the rocker switch 

to the left, auto position. Press the up/down arrows below the time display 

until you reach the desired time. While running unit in timed mode, the time 

display will show time remaining, counting down to zero (0:00).

    •   To run in continuous mode (accumulated time), reset the timer to zero (0:00) 

before running. Time display will show the accumulated time and run until 

you press the rocker switch to the center, standby position.

  Pulse operation: (for Pulsing Vortex Mixer only)

    •  Set the time if desired.

    •   Move the rocker switch to the right, on position. Press the pulse button, in 

the center of the front panel. The speed display will show “PULSE”. The unit 

will run at 3000rpm, cycling a run time of 30 seconds, followed by a resting 

time of 10 seconds. The unit will continue vortexing until the timer reaches 

zero (0:00) or you stop the unit by moving the rocker switch to the center, 

standby position.

4.  When finished with either continuous, intermittent or pulse operation, return rocker 

switch to the center, standby position.

5.  The continuous, on mode is for the larger accessories. In continuous on mode, DO 

NOt run the unit above 900rpm.

6.   The intermittent, auto mode is intended for short mixing times of one (1) minute 

or less at full speed. A rest period of two (2) minutes is recommended to minimize 

the possibility of overheating the motor. The unit can become warm to the touch 

with constant use. There is nothing wrong with it. At high performance settings 

the motor (UL recognized component) simply puts out more heat. iMPOrtaNt

When using larger accessories (Insert Retainer with foam inserts or Ampule Tube 

Holders), DO NOt run the unit above 900rpm. uNit DaMagE WiLL OCCur.

7.   To completely cut off power to the unit, disconnect the power cord from the wall 

outlet.

D

igital

 & P

ulsing

 v

ortex

 m

ixer

 o

Perating

 i

nstructions

7

Summary of Contents for Basic Vortex

Page 1: ...Instruction Manual Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer Instruction Manual...

Page 2: ..._____________ Package Contents Fixed Speed Analog Digital or Pulsing Vortex Mixer 72 183cm power cord 1 cup head 1 3 7 6cm head 1 3 7 6cm rubber head cover Instruction manual Warranty card These acces...

Page 3: ...r check to ensure that no damage has occurred during shipment It is important that any damage that occurred in transport is detected at the time of unpacking If you do find such damage the carrier mus...

Page 4: ...power supply prior to maintenance and servicing Spills should be removed promptly Do not immerse the unit for cleaning Do not operate the unit if it shows signs of electrical or mechanical damage Ear...

Page 5: ...peed 2500rpm Analog Vortexer Mixer Specifications Overall dimensions L x W x H 8 x 5 x 5 25 20 3 x 12 7 x 13 3cm Electrical 50 60 Hz 120V 1 2 amps 150 watts 230V 0 6 amps 150 watts Speed range 300 to...

Page 6: ...time is remaining timed mode The display range is from 0 to 9 999 minutes in one 1 second increments The display will indicate minutes and seconds until the timer reaches 99 minutes and 59 seconds 99...

Page 7: ...wall outlet 1 Make sure the 3 way rocker switch is in the center off position Plug the power cord into a properly grounded outlet 2 For continuous operation push the rocker switch to the right on posi...

Page 8: ...zero 0 00 To run in continuous mode accumulated time reset the timer to zero 0 00 before running Time display will show the accumulated time and run until you press the rocker switch to the center sta...

Page 9: ...ress center of head down firmly until it snaps into place DO NOT use a 3 head without the 3 rubber head cover Add samples to attachments after the head is secured onto the Vortex Mixer Be sure samples...

Page 10: ...ill hold the Single Tube Holder in place To realign this attachment pull up from the handle until the magnets release check the alignment and place again 4 Now that the Single Tube Holder is in place...

Page 11: ...on cup head several times to confirm no obstruction exists If problem persists please contact your Talboys representative for repair Unit is excessively noisy Sensor fan misaligned or Motor misaligne...

Page 12: ...l for mixing up to 8 50mL centrifuge tubes Requires Insert Retainer Description Part Number 20 to 25mm Tube Holder 2 pk 945636 Insert Retainer 945631 Flat Foam Insert Ideal for custom applications Can...

Page 13: ...taches to the top of any Vortex Mixer with the use of a strong magnetic base Accepts tubes from 2 5 to 4 5 6 4 to 11 4cm in length Minimum tube diameter of 0 75 1 9cm Part Number 945659 0 5mL Micro Tu...

Page 14: ...201 Wolf Drive PO Box 87 Thorofare NJ 08086 Phone 1 888 TALBOYS Fax 856 686 1601 E mail troemner troemner com www troemner com 715027 00 REV 6 8 14 Manufactured by...

Reviews: