background image

Talamex inflatable boats – User’s manual 

Pagina 15 van 17 

 

- Do not fill the tanks to the brim. The fuel increases 
volume with a rise in temperature and there is a 
possibility of the tank overflowing or even breaking. 
 

High altitude use 

Normal full inflation pressure is 330 mbar. If boat is 
inflated at sea level (low altitude) and transported to 
a high altitude (i.e., for use in a mountain lake) the 
air pressure must be reduced at the higher altitude to 
prevent over inflation. 
 

5.5   

Reboarding 

 

In the event you fall out of the boat, use the 
following re-boarding procedure to get back into the 
boat. 

 

Hold onto the lifeline fixed to the top of the hull 
side tubes. 

 

Hold your breath and duck down whilst holding 
on to the lifeline. Kick down hard to force your 
body upwards. Your aim is to get as much 
momentum as possible. As your body is coming 
up, use your arms to push down on the hull tube 
to get your stomach on to the tube and your 
upper body as far into the boat as you can. 

 

Using your arms, press down onto the floor 
close to hull tube to get the rest of your body 
over the tube and into the boat. Use one hand to 
reach the opposite lifeline to assist if possible. 

 

Proceed immediately to shore or mother ship 
whichever is nearest. 
 

 

6. 

Maintenance 

6.1 

General maintenance 

Cleaners 

Cleaners special for inflatable boats, should be used 
only and not discharged into waterways. Never mix 
cleaners and be sure to use plenty of ventilation in 
enclosed area. DO NOT use strong detergents, 
solvents or products, which contain phosphates, 
chlorine, solvents, non-biodegradable or petroleum 
based products. Cleaning your Talamex boat can best 
be done using special cleaner for inflatable boats. 

IMPORTANT: 

Waxes or cleaners containing 

alcohol or hydrocarbons SHOULD NOT BE USED 
on the boat fabric. These products will prematurely 
dry out or damage the boat fabric. 

 

IMPORTANT: 

Wash boat with fresh water after use 

of soap and cleaners. 

 

6.2 

Repairs 

If you have any damage to your Talamex inflatable 
boat, it is strongly advised to go to your Talamex 
Boat dealer for repairs.  
If the damage is a small puncture you can use the 
material you find in the repair kit. 
Larger areas or if patch will overlap a seam should be 
patched by a professional repair technician at an 
inflatable repair station. Contact your local Talamex 
dealer for the nearest inflatable repair station. 

Loss of air pressure 

If the boat loses air pressure, first check the valves. 
Use a plant sprayer to spray a mix of water and 
soap on and around the valves. If you see air 
bubbles around the valves, please take the 
following steps: 

 

Take the valve key out of your repair kit. 

 

Put the valve key into the valve and turn the key 
clockwise and check for air bubbles again. 

 

If the valve still leaks, take back of valve in your 
hand and turn the valve stem with the key to the 
left (anti-clockwise) and take out the valve stem. 

 

Inspect the valve on damage. 

 

If there is any damage (see warranty conditions 
point 7), take the defective valve to your selling 
dealer.  

 

Reinstall and lubricate valve stem with silicone 
or soapy water solution to ease installation. 

 

In case of persistent air leakage, contact your 
dealer and check warranty conditions. 

 
PVC repairs 

For the best results when gluing, the relative 
humidity should be less than 60%, ambient air 
temperature should be between 18 °C to 25 °C (65 °F 
to 77 °F) and not in direct sunlight. 

In general, work as follows: 

 

Cut out a patch large enough to overlap the 
damaged area by 30 mm from all sides. 

 

Centre the overlapping patch over the damaged 
area and trace with a pencil the outline of the 
patch. 

 

Clean the surroundings of the puncture and the 
patch. 

 

Apply two thin layers of adhesive using a short 
bristle brush, in a circular pattern on both the 
backside of the patch and the patch area on the 
boat. Allow the first layer to dry completely 
(approximately 15 minutes) before applying the 
second layer. The second layer should dry until 
tacky, then apply the patch to the prepared area 
and press down firmly. Using a smooth object 
(the back of a tablespoon works well), force out 
any air bubbles that may have been trapped 
under the patch, working from the center of the 
patch to the outside. 

Summary of Contents for QLS200

Page 1: ...Talamex inflatable boats User s manual TLM GB2021 01 Pagina 1 van 17...

Page 2: ...3 5 Floorboard 9 3 6 Installing aluminium floor 9 3 7 Installing airfloor 10 3 8 Installing slatted floor 10 3 9 Slide drain valve 10 3 10 Drain plug Alu Rib models 10 3 11 Engine installation 10 3 1...

Page 3: ...Talamex inflatable boat properly and make allowance for the deterioration that will occur in time and as a result of heavy use or misuse of the Talamex inflatable boat Any Talamex inflatable boat no...

Page 4: ...influence of alcohol or drugs while boating it is the law Alcohol or drug use impairs your judgment and greatly reduces your ability to react quickly Prepare other boat operators Instruct at least on...

Page 5: ...hese actions warning Be cautious when refuelling e g no smoking and direct treatment of fuel spillage in craft Prevent the fuel lines from damaging when installing the engine Avoid and prevent contact...

Page 6: ...5 2 V 350 172 45 59 696 20 14 7 60 5 Kort 3 1 116 x 60 x 30 TLRA270 C 6185 2 V 270 163 42 38 370 10 7 4 45 3 1 Kort 3 220 x 100 x 50 HXL195 D 195 143 42 21 360 3 5 2 6 20 2 Kort 3 1 1 90 x 43 x 20 HXL...

Page 7: ...Talamex inflatable boats User s manual Pagina 7 van 17 2 10 Drawings...

Page 8: ...e tube right above the floor If the oars are not in use put the oars in the clips on the sides of the boat with the blade pointing to the transom 3 3 Seatbench Inflate the boat for 75 and install the...

Page 9: ...r Deflate the keel and deflate the boat for about 2 3 Place the front section bow board 1 of the floorboard as far in the front of the boat as possible Make sure the hole in the bottom is straight abo...

Page 10: ...tubes as far as possible Inflate the air floor to minimum 700 mb maximum 825 mb Inflate the keel Close the valves by putting the caps on top of it and turning them to the right 3 8 Installing slatted...

Page 11: ...d properly eventually use the spacers not delivered with all models to determine the right height of the motor A motor installed improperly may cause spray water or cavitation racing of the motor Star...

Page 12: ...bow handle and or handgrips See drawing 2 10 for location of these components IMPORTANT Remove outboard engine fuel tank all equipment and make sure no passengers are onboard during lifting and or tow...

Page 13: ...nows safe navigation boating and operating procedures A ring type life buoy or buoyant cushion designed to be thrown to a person in the water Arrange passengers and load in the boat so the weight is d...

Page 14: ...boat skin Turning the boat When taking a sharp turn reduce the speed of your boat The boat will tilt considerably inside towards the turning centre 5 4 Hazards Air chamber failure Your Talamex boat is...

Page 15: ...it is strongly advised to go to your Talamex Boat dealer for repairs If the damage is a small puncture you can use the material you find in the repair kit Larger areas or if patch will overlap a seam...

Page 16: ...sh water Dry all parts before storage in the carrying bag This will help prevent mold or mildew 2 The transom should be inspected for damage or deterioration of the finish Scratches or abrasions shoul...

Page 17: ...orrect harbouring beaching towing mooring lifting collision incorrect use of a trailer I Damage as a result of theft or fire J Damage caused by rainfall from the sky tree juices spilling of chemicals...