Initial sensitivity setting function --- when turning on the power
When you turn on the power, the initial sensitivity setting function runs for about three seconds.
While the initial sensitivity setting function is running (about 3 seconds ), the green and orange LED on the front of the sensor blinks.
When the initial setting is completed, greed LED turns on.
●
Automatic sensitivity resetting function --- during operation (You can turn this feature on or off with a switch.)
When an object continues to be detected for a long time (about 20 seconds), which might occur due to dirt and dust on the lens
or optical axis deviation, the automatic sensitivity resetting function runs and the optimal sensitivity is set again. Use the DIP switch
to turn this feature on or off.
●
Job indicator and Fault indicator
●
Operation indicator
Operation indicator: Orange LED
Initial sensitivity setting indicator: Green/Orange LED
It lights up when the output is ON (Close).
Green: Green LED turns on when teaching is completed.
Orange/ Green blinking: Orange and Green lights blink while teaching is being
performed.
No object
Sensor detection
Job indicator input
Job indicator: Green
Fault indicator: Red
ON
Blinking
Object
No object
Object
Blinking
2
3
4
5
6
1
DIFFUSE
AUTO
ADJUST
PNP
FREQ. A
N.O.
F.L. ON
RETRO
AUTO
ADJ OFF
NPN
FREQ. B
N.C.
F.L. OFF
Automatic sensitivity resetting
Operation mode
Fault indicator
NPN/PNP output
frequency switch
●
Before setting the mode selector switch,
be sure to turn off the power.
●
By setting slide switches inside the sensor,
you can select the functions below.
1
2
Automatic sensitivity resetting
Select whether Automatic sensitivity resetting is activated.
AUTO ADJ UST: Automatic sensitivity resetting is activated
AUTO ADJ OFF: Automatic sensitivity resetting is NOT activated
3
Operation mode
Select output mode.
N. O.: Normal Open
Close when detecting an object
N. C.: Normal Close
Open when detecting an object
4
1
2
3
4
5
6
Fault indicator
Select whether Fault indicator is activated.
5
NPN/PNP output
Select Job indicator input and output type.
6
Frequency switch
With the frequency switch, either A or B of different
frequencies can be set.
When the sensor detects an object while there is
no Job indicator input, the red light of Fault indicator blinks.
507
L
ig
h
t C
u
rta
in
Se
n
so
rs
SSP-S200
■
Mode selector switch
■
Indicators
■
Initial sensitivity setting function