Names of the Operation Section

Note: This section describes the name and function of each part used during optical axis adjustment.

Upper transmission/reception authorization LED

Lower transmission/reception authorization LED

Each time the switch is pressed, the optical unit that transmits the light switches.

Transmitter

Receiver

Upper/lower changeover switch

Near

Far

Near

Far

(High accuracy)

6-1

NAMES AND FUNCTIONS OF OPTICAL AXIS ADJUSTMENT PARTS

OPTICAL AXIS ADJUSTMENT

Names of the Optical Unit

Horizontal

Re

fl

ector Section Horizontal/Vertical Angle Adjustment Method

Vertical

Fine adjustment

Coarse adjustment

Fine adjustment

6

Transmit from both upper and lower

Only transmit 
from upper

Only transmit 
from lower

No transmission

Received on both upper/lower

Only received on lower

Only received on upper

Each time the switch is pressed, the optical unit that receives the light is switched.

Swing arm
(Red)
Note: For vertical 

angle 
adjustments

Horizontal angle fine adjustment screw
(White)
Note: For horizontal angle adjustments

Vertical angle adjustment screw
(Red)
Note: For vertical angle 

adjustments

Swivel base
(White)
Note 1: For horizontal angle 

adjustments

Note 2: Single notch is 

equivalent to 3°

Note: Sequence of 

adjustment

When the view finder is 
looked closely, view appears 
as the diagram on the right.
Adjust the angle so that the 
target color appears in the 
center of the ring. 

When the view finder is 
looked from a distance, the 
view appears as the diagram 
on the right.
Adjust the angle so that the 
target color appears in the 
center of the ring. 

Double Ring Alignment Mechanism 
Visible from the view finder

View finder

Coarse adjustments can be made 
by moving the swivel base 
within the range of 0˚ to ±90˚.

Next, fine adjustments of 0˚ to ±5˚ 
can be made using the horizontal 
angle adjustment screw.

Horizontal angle fine 
adjustment screw

The inclination of the reflector can be 
switched between -10˚ and +10˚ by 
pushing it forwards or backwards.

Next, fine adjustments of 0˚ to ±10˚ 
can be made using the vertical angle 
adjustment screw.

By aligning the optical axis correctly, a protection line with sufficient margin 
of sensitivity can be created, reducing the occurrence of malfunction. 
Always adjust the optical axis on both upper and lower levels.

Alarm LED
Note: Only available 

on the receiver

• Lights up when an 

alarm is output.

Sensitivity attenuation 
LED
Note: Only available on 

the receiver

• Lights up when the 

sensitivity is 
insufficient.

The corresponding LED lights up when the 
light transmission/reception is authorized. 
(The upper and lower can be switched by 
he upper/lower changeover switch.)

Monitor jack Note: Only available on the receiver
    • The monitor output voltage can be checked by using a commercially available tester.

Sound check switch Note: Only available on the receiver
    • Light reception level can be checked by the sound tone.
      In the walk test mode, the beep sound is generated according to the alarm output.

Summary of Contents for PXB-50F

Page 1: ...to receiver for the transmitted light as shown in the illustration on the right The infrared light transmitted from the transmitter expands in a cone shape while the light beams enter the receiver The straight line that connects the transmitter with the receiver is the detection line If the detection line is obstructed light is obstructed for more than 0 05 0 7 seconds the receiver detects this br...

Page 2: ...ION SECTION 2 PRECAUTIONS 3 PRECAUTIONS 3 1 PROTECTION DISTANCE AND RANGE OF LIGHT BEAM COVERAGE 3 2 MOUNTING HEIGHT 3 3 OPTICAL AXIS ADJUSTMENT RANGE 3 4 EXAMPLE OF PRACTICAL APPLICATION 4 INSTALLATION METHOD 4 1 WALL INSTALLATION METHOD 4 2 POLE INSTALLATION METHOD 5 WIRING METHOD 5 1 POSITION AND RATING OF TERMINALS 5 2 WIRING DISTANCE BETWEEN SENSOR AND POWER SUPPLY 5 3 WIRING DISTRIBUTION DIA...

Page 3: ...d with a voltage level other than the indicated power supply voltage specified between 10 to 30V DC Doing so may cause a fire or electrical shock Do not connect a device that exceeds the capacity shown to the output contact of this device Doing so may cause a fire or electrical shock Do not touch the terminal section with wet hands Doing so may cause an electrical shock Do not disassemble or modif...

Page 4: ...WFO JG UIF SFDFJWFS JT BU UIF DFOUFS PG UIF MJHIU CFBNT NBLJOH UIF TZTUFN NPSF TVTDFQUJCMF UP BEWFSTF FGGFDUT PG UIF FOWJSPONFOU SFTVMUJOH JO B NBMGVODUJPO Approx 2 6 0 8m OTUBMMJOH TP UIBU UIF DFOUFS PG UIF TFOTPS JT BQQSPYJNBUFMZ GU 8N GSPN UIF HSPVOE NFBOT UIBU UIF QSPUFDUJPO MJOF JT BU XBJTU IFJHIU GPS IVNBOT FOBCMJOH SFMJBCMF EFUFDUJPO G UIF JOTUBMMBUJPO QPTJUJPO JT UPP IJHI PS UPP MPX UIF QS...

Page 5: ...ed protection Don t install transmitters in the same direction for straight line protection Refer to the diagram below and install the sensors within the optical axis adjustment range Photoelectric beams are drawn in simplified form In order to minimize the occurrence of malfunctions refer to the protection diagram below for optimal operation Using the sensors incorrectly may cause malfunction Lig...

Page 6: ...UFSJBM UISPVHI UIF HSPNNFU t UUBDI UIF JOTUBMMBUJPO QMBUF BOE TFDVSF JU CZ UJHIUFOJOH the screws This work is required as an insect proof and drip proof countermeasure for the sensor exterior PUF PS XJSJOH XJUI BO FYUFSOBM EJBNFUFS PG φ NN UP φ NN CSFBL UIF NFNCSBOF CZ QSFTTJOH JU UISPVHI UIF SFDFTT PUF PS XJSJOH XJUI BO FYUFSOBM EJBNFUFS FYDFFEJOH φ NN DVU PGG UIF section shown by the dotted line...

Page 7: ...UIF QPMF JOTUBMMBUJPO ĀUUJOHT 4FDVSF JU UP UIF FOE PG UIF QPMF t 1BTT UIF XJSJOH QVMMFE GSPN UIF QPMF UISPVHI UIF HSPNNFU t JY UIF JOTUBMMBUJPO QMBUF UP UIF QPMF VTJOH UIF JOTUBMMBUJPO ĀUUJOHT Cover fixing screws Sensor fixing screws 5IJT XPSL JT SFRVJSFE BT BO JOTFDU QSPPG BOE ESJQ QSPPG DPVOUFSNFBTVSF GPS UIF TFOTPS FYUFSJPS 5IJT XPSL JT SFRVJSFE BT BO JOTFDU QSPPG BOE EVTU QSPPG DPVOUFSNFBTVSF ...

Page 8: ...ng installation carry out pipe laying work whenever possible 3 Never use overhead wiring Part No Supply voltage PXB 50F 12V DC 24V DC 12V DC 24V DC 12V DC 24V DC PXB 100F PXB 200F t Transmitter Transmitter Transmitter Transmitter Transmitter Receiver Receiver Receiver Receiver Receiver Alarm signal 1 b contact Alarm signal 2 b contact Power supply 12 V DC Alarm signal b contact Tamper signal b con...

Page 9: ...e target color appears in the center of the ring When the view finder is looked from a distance the view appears as the diagram on the right Adjust the angle so that the target color appears in the center of the ring Double Ring Alignment Mechanism Visible from the view finder View finder Coarse adjustments can be made by moving the swivel base within the range of 0 to 90 Next fine adjustments of ...

Page 10: ...finder and adjust the position so that the sensor of the opposite device is visible at the center of the ring using the horizontal and vertical angle fine adjustment screws Look through the view finder from a distance and readjust so that the sensor of the opposite device is visible at the center of the ring using the horizontal and vertical angle fine adjustment screws 1 The light enters the rece...

Page 11: ...receiver to select Reception authorization on upper only 3 Turn the adjustment screw to fine adjust until the tone reaches the highest pitch Adjust both the transmitter and receiver 3 Fine adjust the lower level optical axis 1 Press the upper lower changeover switch on the transmitter to select Only transmit from lower 2 Press the upper lower changeover switch on the receiver to select Reception a...

Page 12: ...smitter to select Only transmit from lower 2 Press the upper lower changeover switch on the receiver to select Reception authorization on lower only 3 Turn the adjustment screw to fine adjust until the monitor output voltage reaches the highest value Adjust both the transmitter and receiver 4 Check if the light from another transmitter enters the receiver 1 Press the upper lower changeover switch ...

Page 13: ...the optical axis away from the reflection surface within the allowable range Perform this for both the transmitter and receiver This device features the functions that must be set for operating the device as well as those that are necessary for adjustment procedures Perform setting and adjustment by checking the following table This section describes the detailed information of the functions that ...

Page 14: ...iring of the transmitter receiver is located nearby a power line 5 Unstable sensor installation 6 Transmitter receiver cover or reflection section is dirty 7 Improper alignment of optical axis 8 A large bird or cat may obstruct the beams 1 Check again 2 Stabilize the supply voltage 3 Remove the object 4 Change the wiring route 5 Fix in a stable location 6 Clean using a soft cloth 7 Perform optical...

Page 15: ...in 2sec Contact capacity 30V AC DC 0 25A resistive load Protective resistor Dry contact relay output form C Action Activated when weather condition gets worse Contact capacity 30V AC DC 0 25A resistive load Protective resistor Dry contact relay N C Action Activated when cover is detached Contact capacity 30V AC DC 0 1A resistive load Protective resistor Terminals 65 Outdoor Indoor Model Detection ...

Page 16: ...takex com Takex Europe Ltd http www takex com In the U S In the U K In Australia 1712 Aviary Court Wade Road Basingstoke Hampshire RG24 8PE U K Tel 44 01256 475555 Fax 44 01256 466268 4 15 Howleys Road Notting Hill VIC 3168 Tel 61 03 9544 2477 Fax 61 03 9543 2342 83 1 Gojo sotokan Higashino Yamashina ku Kyoto 607 8156 Japan Tel 81 75 501 6651 Fax 81 75 593 3816 151 San Zeno WAY Sunnyvale CA 94086 ...

Reviews: