Transmitter
Receiver
Power supply
(12 V DC)
Alarm signal
(b contact)
Power supply
(12 V DC)
Power supply
(12 V DC)
Alarm signal
(b contact)
Environment signal (b contact)
(Controller)
(Controller)
(Controller)
(Controller)
5
WIRING METHOD
WIRING DISTRIBUTION DIAGRAM (WIRING DIAGRAM)
5-3
WIRING DISTANCE BETWEEN SENSOR AND POWER SUPPLY
5-2
POSITION AND RATING OF TERMINALS
5-1
VACANT
11
10
8
7
6
NO
NC
COM
9
5
4
3
NO
NC
COM
2
1
<Transmitter>
<Receiver>
12 to 30V DC
Power input
(no polarity)
Current consumption: PXB- 50F: 9mA
PXB-100F:11mA
PXB-200F:13mA
12 to 30V DC
Power input
(no polarity)
Current consumption: PXB- 50F: 19mA
PXB-100F: 19mA
PXB-200F: 19mA
Alarm output
30V (AC/DC) 0.25A (Resistance load)
No-voltage relay contact: c contact
Built-in contact protection resistance
Environmental output
30V (AC/DC) 0.25A (Resistance load)
No-voltage relay contact: c contact
Built-in contact protection resistance
Tamper output
30V (AC/DC) 0.1A
No-voltage contact: b contact
Built-in contact protection resistance
Tamper output
2
1
11
10
Basic connections
When multiple sensor units are connected
to the same circuit
For environmental output, tamper output
When multiple sensor units are connected
to separate circuits
[Precautions for Installation]
(1) Signal output for the upper and lower levels of the receiver cannot be output separately.
(2) For outdoor wiring installation, carry out pipe laying work whenever possible.
(3) Never use overhead wiring.
Part No.
Supply v
oltage
PXB-50F
12V DC
24V DC
12V DC
24V DC
12V DC
24V DC
PXB-100F
PXB-200F
t
Transmitter
Transmitter
Transmitter
Transmitter
Transmitter
Receiver
Receiver
Receiver
Receiver
Receiver
Alarm signal 1
(b contact)
Alarm signal 2
(b contact)
Power supply (12 V DC)
Alarm signal (b contact)
Tamper signal (b contact)
Up to 2,700ft. ( 823m)
Up to 4,200ft. (1,280m)
Up to 5,100ft. (1,550m)
Up to 6,600ft. (2,000m)
Up to 8,300ft. (2,500m)
Up to 10,500ft. (3,200m)
30V (AC/DC) 0.1A
No-voltage contact: b contact
Built-in contact protection resistance
⑧
When 2 or more units are connected, the wiring distance is calculated as follows: [Above value/number of units]
AWG 20 (Dia,0.8mm)
AWG 18 (Dia,1.0mm)
AWG 17 (Dia,1.1mm)
AWG 16 (Dia,1.25mm)
AWG 15 (Dia,1.4mm)
AWG 14 (Dia,1.6mm)
Up to 19,000ft. ( 5,790m)
Up to 29,500ft. ( 8,990m)
Up to 36,000ft. (11,000m)
Up to 46,000ft. (14,000m)
Up to 58,000ft. (17,700m)
Up to 76,000ft. (23,200m)
Up to 2,500ft. ( 750m)
Up to 3,800ft. (1,160m)
Up to 4,800ft. (1,460m)
Up to 6,200ft. (1,890m)
Up to 7,800ft. (2,380m)
Up to 10,000ft. (3,000m)
Up to 17,000ft. ( 5,200m)
Up to 27,500ft. ( 8,380m)
Up to 33,000ft. (10,000m)
Up to 43,000ft. (13,100m)
Up to 53,000ft. (16,000m)
Up to 71,000ft. (21,600m)
Up to 2,300ft. ( 700m)
Up to 3,700ft. (1,130m)
Up to 4,500ft. (1,370m)
Up to 5,800ft. (1,770m)
Up to 7,300ft. (2,350m)
Up to 9,500ft. (2,900m)
Up to 16,000ft. ( 4,880m)
Up to 25,000ft. ( 7,500m)
Up to 31,000ft. ( 9,500m)
Up to 40,000ft. (12,000m)
Up to 51,000ft. (15,500m)
Up to 66,000ft. (20,000m)
Size of
electrical cable used