background image

TROUBLESHOOTING

Daily Inspections

9

(1) Power is not on
(2) Poor wiring or breaking of wire, short
(3) Transmitter is set to [Do not transmit]

(1) Connect the power source
(2) Check again
(3) Press the upper/lower changeover switch

(1) Power is not on
(2) Poor wiring or breaking of wire, short

(1) Connect the power source
(2) Check again

(1) Connect the power source
(2) Check again
(3) Remove the reflecting object, or change 

the installation location or optical axis 
direction

(4) Obstruct four levels simultaneously
(5) Shorten the detection response time

(1) Power is not on
(2) Poor wiring or breaking of wire, short
(3) Photoelectric beam is reflected by some object and 

entering the receiver

(4) Four levels are not obstructed simultaneously
(5) Sensor beam is obstructed for less time than the 

detection response time setting in the receiver

(1) Optical axis (alignment) is not aligned correctly

(2) There is an obstruction between the transmitter and 

receiver

(3) Transmitter/receiver cover or reflection section is dirty
(4) Frequency channel settings on the transmitter and 

receiver do not match

(1) Poor wiring connection
(2) Change of supply voltage
(3) Obstruction between transmitter and receiver (objects 

such as branches that move with the wind)

(4) The wiring of the transmitter/receiver is located nearby 

a power line

(5) Unstable sensor installation
(6) Transmitter/receiver cover or reflection section is dirty
(7) Improper alignment of optical axis

(8) A large bird or cat may obstruct the beams

(9) Transmission power switch is set to L, which does not 

keep enough margin of sensitivity

(1) Check again
(2) Stabilize the supply voltage
(3) Remove the object

(4) Change the wiring route

(5) Fix in a stable location
(6) Clean using a soft cloth
(7) Perform optical axis adjustment again, set 

the gain lock and secure the margin of 
sensitivity

(8) Set the response time to be slightly longer 

(however, this is not possible if there is a 
possibility that an intruder could run 
through at top speed)

(9) Set the transmission power switch to H, 

remove the receiver cover and set the gain 
lock again

(1) Perform angle adjustment again and set 

the gain lock

(2) Remove the object

(3) Clean using a soft cloth
(4) Readjust the frequency channels so they 

are the same

Transmitter LED does not 

light (cover is open)

Alarm LED does not go out

(Alarm output does not stop)

Continually activated

Status

Cause

Remedy

Alarm LED does not light 

even if the photoelectric 

beam is obstructed

• Check the device by referring to the table below. If you cannot restore the device to a 

normal condition after the check, contact the place of purchase or TAKEX.

To clean the device, use a soft, wet cloth and then wipe off any water drops.
If the device is particularly dirty, dip the soft cloth in water that includes a weak neutral detergent. 
Wipe the device gently with the cloth, then wipe off any detergent that remains. 
Do not use substances such as thinner or benzene. (The plastic parts may deform, discolor or change their properties.)

Perform operation checks on a regular weekly basis.

Beam reception authorization 

LED does not light

 (cover is open)

Summary of Contents for PXB-100SW

Page 1: ...ansmitter with the receiver is the detection line If the detection line is obstructed light is obstructed for more than 0 05 0 7 seconds the receiver detects this break in the light beams and outputs...

Page 2: ......

Page 3: ...Factory setting N C 8 EXPLANATION OF FUNCTIONS 8 8 ENVIRONMENTAL OUTPUT SELECTION FUNCTION Environmental output changeover switch Factory setting N C Light reception channel changeover switch Factory...

Page 4: ...0 8m from the ground means that the protection line is at waist height for humans enabling reliable detection If the installation position is too high or too low the protection line will be above sho...

Page 5: ......

Page 6: ......

Page 7: ...to Caution A B If the plate is removed the plate will also fall off the pole When replacing the sensor keep both plates to the pole and replace only the sensor unit...

Page 8: ......

Page 9: ...r 1CH Transmitter 1CH Receiver 1CH Transmitter 3CH Receiver 3CH Receiver Receiver Receiver RF transmitter RF transmitter RF transmitter RF transmitter RF transmitter Basic connection 1 zone connect al...

Page 10: ...ange of 0 to 90 Next fine adjustments of 0 to 5 can be made using the horizontal angle adjustment screw Fine adjustments Horizontal angle fine adjustment screw Coarse adjustments Fine adjustments The...

Page 11: ...djust so that the sensor of the opposite device is visible at the center of the ring using the horizontal and vertical angle fine adjustment screws Turn on the power to the transmitter and receiver ch...

Page 12: ...itter to select Only transmit from upper 2 Press the upper lower changeover switch on the receiver to select Reception authorization on upper only 3 Turn the adjustment screw to fine adjust until the...

Page 13: ...smit from lower 2 Press the upper lower changeover switch on the receiver to select Reception authorization on lower only 3 Turn the adjustment screw to fine adjust until the monitor output voltage re...

Page 14: ......

Page 15: ...ON OFF...

Page 16: ...the light reception level for both the upper and lower beams recovers to the specified level for 5 seconds at the shortest Using the alignment wireless checker that is sold separately enables easy an...

Page 17: ...d or cat may obstruct the beams 9 Transmission power switch is set to L which does not keep enough margin of sensitivity 1 Check again 2 Stabilize the supply voltage 3 Remove the object 4 Change the w...

Page 18: ...2 Receiver Max 3 1mA 1 Max 10 7mA 2 10 to 30V DC Dry contact relay output N C N O switchable Contact action Interruption time Min 2sec Contact capacity 30V AC DC 0 25A resistive load Protective resis...

Page 19: ......

Page 20: ......

Reviews: