background image

Main Features

(1) DOUBLE MODULATION

(2) WIDE BEAM

(3) QUAD HIGH POWER BEAM

(4) LOW CURRENT CONSUMPTION

(5) ECOLOGY

(6) DUAL RING SIGHT

(7) TARGET COLOR

(8) INCREASED ANGLE 

ADJUSTMENT ALLOWANCE

(9) WIRELESS ALIGNMENT CHECKER

(10) LIGHTNING PROTECTION

The vivid color of the internal structure can be 
recognized easily from the far end in the beam 
alignment procedure. 
The color differs between a transmitter and a 
receiver which helps easy installation and 
checking.

Enables easy and accurate beam alignment. 
(Sold separately)  

Minimize the damage by the induced thunder 
through wirings. 
It may stand 10000V under normal mode, 
15000V under common mode.

Vertically ±20˚ compared with previous version. 
It may adapt to the slope installation fl exibly.

Enables better and clear view for easy beam 
alignment.

This device is an opposed type photoelectric beam sensor that consists 
of a photo transmitter that transmits infrared light, and a photo 
receiver for the transmitted light, as shown in the illustration on the 
right.
The infrared light transmitted from the transmitter expands in a cone 
shape, while the light beams enter the receiver.
The straight line that connects the transmitter with the receiver is the 
detection line.
If the detection line is obstructed (light is obstructed for more than 
0.05 – 0.7 seconds), the receiver detects this break in the light beams, 
and outputs a signal.
In order to ensure that the detection line has sufficient margin of 
sensitivity, adjust the direction of the light beams before placing the 
system into operation. Providing sufficient margin of sensitivity 
reduces the occurrence of malfunction caused by dense fog, heavy rain, 
frost, snow, and other such weather conditions. 

Double modulated beams are designed to 
distinguish the external lights.
It increases the reliability in the outdoor security 
system.

The pitch between upper beam and lower one is 
widened more than old models.
False alarm by birds and falling leaves reduces 
drastically. 

The beam power is 100 times of  the minimum 
requirement.  
The beam distance is 10 times of the described 
specifi cation. 
This high power beam also realizes the reliability 
against the harsh conditions like fog, snow, heavy 
rain. 

50% less than remaining models. The battery size 
may reduce, wiring diameter may lessen, 
installation cost may decrease.

RoHS adapted – Environment friendly.  Free from 
Lead, Mercury, Cadmium, Hexavalent chromium, 
Polybrominated biphenyl, Polybrominated diphenyl 
ether.

Instruction Manual

PHOTOELECTRIC BEAM SENSOR

PXB-   50HF-KH: OUTDOOR 165ft (  50m)
PXB- 100HF-KH: OUTDOOR 330ft (100m)
PXB- 200HF-KH: OUTDOOR 660ft (200m)

Thank you for purchasing this product.
Read this instruction manual before using the product to make sure that you use it correctly.

Coverage of light beams 

Detection line 

Receiver 

Transmitter  

Summary of Contents for PXB-100HF-KH

Page 1: ...econds the receiver detects this break in the light beams and outputs a signal In order to ensure that the detection line has sufficient margin of sensitivity adjust the direction of the light beams b...

Page 2: ...NTING HEIGHT 4 3 3 OPTICAL AXIS ADJUSTMENT RANGE 5 3 4 EXAMPLE OF PRACTICAL APPLICATION 5 4 INSTALLATION METHOD 4 1 INSTALLATION INTO HOUSING 6 5 WIRING METHOD 5 1 POSITION AND RATING OF TERMINALS 6 5...

Page 3: ...e Doing so may cause a fire electrical shock or malfunction of the device If smoke or an abnormal odor or sound is found leaving it unattended may cause a fire or electrical shock Immediately turn off...

Page 4: ...ric beam sensors causing erroneous detections Therefore be sure to prune such plants regularly 3 Other natural phenomena such as insects or bird droppings may soil the sensors causing miss detection B...

Page 5: ...w t VUVBM JOUFSGFSFODF PS XSBQBSPVOE PG UIF QIPUPFMFDUSJD CFBNT DBO CF QSFWFOUFE CZ DIBOHJOH UIF DIBOOFMT i 91 5 0 0 6 5 0 4 0 6 5 0 3 26 07 3 6 5 0 w PUF 4FU DPSSFTQPOEJOH USBOTNJUUFST BOE SFDFJWFST...

Page 6: ...tact c contact Built in contact protection resistance Auto gain lock control 2 1 Size of electrical cable used Part No Supply voltage Up to 16 000ft 4 880m Up to 2 200ft 670m Up to 15 000ft 4 570m AWG...

Page 7: ...its are connected to the same circuit Basic connections for 2 level protection For environmental output tamper output and alarm memory display in the remote mode When multiple sensor units are connect...

Page 8: ...within the range of 0 to 90 Next fine adjustments of 0 to 5 can be made using the horizontal angle adjustment screw Fine adjustments Horizontal angle fine adjustment screw Rough adjustments Fine adju...

Page 9: ...djust so that the sensor of the opposite device is visible at the center of the ring using the horizontal and vertical angle fine adjustment screws Turn on the power to the transmitter and receiver ch...

Page 10: ...aches the highest pitch Adjust both the transmitter and receiver 3 Fine adjust the lower level optical axis 1 Press the upper lower changeover switch on the transmitter to select Only transmit from lo...

Page 11: ...Press the upper lower changeover switch on the receiver to select Reception authorization on lower only 3 Turn the adjustment screw to fine adjust until the monitor output voltage reaches the highest...

Page 12: ...center of the detection line and check that an alarm can be output correctly In using the environmental output confirm that the environmental output is generated when the optical axes in both the upp...

Page 13: ...n 500ft 150 m Model L H Power PXB 100HF KH PXB 200HF KH E g 200 60 m 295 90 m When PXB 100HF KH is set at a distance of 295ft 90 m set to H When PXB 100HF KH is set at a distance of 200ft 60 m set to...

Page 14: ...or upper and lower Note Only installed on the receiver The margin of sensitivity on this device is set so that an appropriate sensitivity can be obtained when the optical axis is aligned while the dev...

Page 15: ...t an intruder could run through at top speed 9 Set the transmission power switch to H remove the receiver cover and set the gain lock again 1 Perform angle adjustment again and set the gain lock 2 Rem...

Page 16: ...ency selection Tone indicator Environmental module Beam power selection Transmitting power adjutment Alarm memory indication Programmed AGC Auto gain lock function Monitorjack Response time adjustment...